From version < 380.1 >
edited by Dilisi S
on 2025/03/25 13:31
To version < 381.1 >
edited by Dilisi S
on 2025/04/01 02:51
>
Change comment: Mar 31 edits - part 1

Summary

Details

Page properties
Content
... ... @@ -47,7 +47,6 @@
47 47  * Supports 2 × AA LR6 batteries
48 48  * IP52-rated for dust and water resistance
49 49  
50 -
51 51  == 1.3  Power Consumption ==
52 52  
53 53  
... ... @@ -54,7 +54,6 @@
54 54  * **Idle:** 5 µA
55 55  * **Transmit:** Max 110 mA
56 56  
57 -
58 58  == 1.4  Storage & Operation Temperature ==
59 59  
60 60  
... ... @@ -71,7 +71,6 @@
71 71  * Smart Cities
72 72  * Smart Factory
73 73  
74 -
75 75  See **Use Cases** for more information.
76 76  
77 77  
... ... @@ -186,7 +186,6 @@
186 186  * **Valid Sensor Value**: Use FPort=2
187 187  * **Other Status / Control Commands**: Use an FPort other than 2.
188 188  
189 -
190 190  === 2.4.1  Uplink FPORT~=5, Device Status ===
191 191  
192 192  
... ... @@ -221,7 +221,6 @@
221 221  * 0x09: AS923-2
222 222  * 0x0a: AS923-3
223 223  
224 -
225 225  (% style="color:#4472c4" %)**Sub-Band**(%%): Value 0x00 ~~ 0x08 (only for CN470, AU915,US915. For others, it's 0x00)
226 226  
227 227  (% style="color:#4472c4" %)**BAT**(%%): Shows the battery voltage for PB05-L.
... ... @@ -606,45 +606,49 @@
606 606  
607 607  (% style="display:none" %) (%%) (% style="display:none" %)
608 608  
609 -== 2.7 Button ==
604 +== 2.7 Buttons ==
610 610  
611 611  
612 -* ACT button
607 +* **ACT button**
613 613  
614 -Long press this button PB05-L will reset and join network again.
609 +Long press the ACT button to reset the device and allow it to join network again.
615 615  
616 616  [[image:image-20250303110613-4.jpeg||height="198" width="472"]]
617 617  
618 -* Alarm button
613 +* **Alarm buttons**
619 619  
620 -The PB05-L has five alarm buttons.
615 +When you press an alarm button, the PB05-L immediately uplinks data. The alarm flag is set to 'TRUE,' and the corresponding button status is 'Yes'.
621 621  
622 -When you press one of the alarm buttons, the PB05-L will immediately uplink data, and the alarm flag is "TRUE", and the corresponding button is "Yes".
623 -
624 624  [[image:image-20250303111505-5.jpeg||height="252" width="374"]](% style="display:none" %)
625 625  
626 626  
627 -== 2.8 LED Indicator ==
620 +== 2.8 LED Indicators ==
628 628  
629 629  
630 630  (((
631 -The PB05-L has a triple color LED which for easy showing different stage.
624 +The** PB05-L** has a **tri-color LED** for easily indicating different stages.
625 +
626 +Hold the **ACT** button until the green light turns on to reset the device. The green LED will flash as the node restarts, the blue LED will flash once when requesting network access, and the green LED will remain on for 5 seconds after successful network access.
632 632  )))
633 633  
634 -Hold the ACT green light to rest, then the green flashing node restarts, the blue flashing once upon request for network access, and the green constant light for 5 seconds after successful network access
635 -
636 636  (((
637 -(% style="color:#037691" %)**In a normal working state**:
638 -)))
630 +**In a normal working state:**
639 639  
640 -* When the node is restarted, hold the ACT (% style="color:green" %)**GREEN**(%%) lights up , then the (% style="color:green" %)**GREEN**(%%) flashing node restarts.The (% style="color:blue" %)**BLUE**(%%) flashing once upon request for network access, and the (% style="color:green" %)**GREEN**(%%) constant light for 5 seconds after successful network access.
641 -* During OTAA Join:
642 -** **For each Join Request uplink:** the (% style="color:green" %)**GREEN LED** (%%)will blink once.
643 -** **Once Join Successful:** the (% style="color:green" %)**GREEN LED**(%%) will be solid on for 5 seconds.
644 -* After joined, for each uplink, the (% style="color:blue" %)**BLUE LED**(%%) or (% style="color:green" %)**GREEN LED** (%%)will blink once.
645 -* Press the alarm button,The (% style="color:red" %)**RED**(%%) flashes until the node receives the ACK from the platform and the (% style="color:blue" %)**BLUE**(%%) light stays 5s.
632 +* When the node restarts, hold the ACT button until the GREEN LED lights up. The GREEN LED will flash as the node restarts.
633 +* The BLUE LED will flash once upon requesting network access.
634 +* The GREEN LED will remain on for 5 seconds after successful network access.
646 646  
647 -(((
636 +**During OTAA Join:**
637 +
638 +* For each Join Request uplink, the GREEN LED will blink once.
639 +* Once the Join is successful, the GREEN LED will remain on for 5 seconds.
640 +* After joining, for each uplink, either the BLUE or GREEN LED will blink once.
641 +
642 +**Alarm Button Press:**
643 +
644 +* When an alarm button is pressed, the RED LED will flash until the node receives an ACK from the platform.
645 +* Once the ACK is received, the BLUE LED will stay on for 5 seconds.
646 +
648 648  
649 649  )))
650 650  
... ... @@ -651,31 +651,30 @@
651 651  == 2.9 Buzzer ==
652 652  
653 653  
654 -The PB05 has** button sound** and** ACK sound** and users can turn on or off both sounds by using [[AT+SOUND>>||anchor="H3.3A0SetbuttonsoundandACKsound"]].
653 +The PB05 has**button sound** and an **ACK sound**, both of which users can turn on or off using [[AT+SOUND>>||anchor="H3.3A0SetbuttonsoundandACKsound"]].
655 655  
656 -* (% style="color:#4f81bd" %)**Button sound**(%%)** **is the music produced by the node after the alarm button is pressed.
655 +* (% style="color:#4f81bd" %)**Button sound**(%%) is the tone played by the node after an alarm button is pressed.
656 +You can use [[AT+OPTION>>||anchor="H3.4A0Setbuzzermusictype2807E429"]] to set different button sounds.
657 +* (% style="color:#4f81bd" %)**ACK sound**(%%) is the notification tone played when the node receives an ACK.
657 657  
658 - Users can use[[ AT+OPTION>>||anchor="H3.4A0Setbuzzermusictype2807E429"]] to set different button sounds.
659 659  
660 -* (% style="color:#4f81bd" %)**ACK sound **(%%)is the notification tone that the node receives ACK.
661 -
662 662  == 2.10 E2 Extension Cable ==
663 663  
664 664  
665 665  [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220619092222-1.png?width=188&height=182&rev=1.1||alt="image-20220619092222-1.png"]][[image:image-20250303135532-3.jpeg||height="184" width="234"]]
666 666  
667 -**1m long breakout cable for PB05-L. Features:**
668 668  
669 -* (((
670 -Use for AT Command, works for both LHT52/LHT65N/PB05-L.
671 -)))
672 -* (((
673 -Update firmware for PB05-L, works for both LHT52/LHT65N/PB05-L.
674 -)))
675 -* (((
676 -Exposed All pins from the PB05-L Type-C connector
677 -)))
666 +**1m Long Breakout Cable for PB05-L**
678 678  
668 +**Features:**
669 +
670 +* Used for AT commands; compatible with LHT52, LHT65N, and PB05-L.
671 +* Supports firmware updates for PB05-L; also works with LHT52 and LHT65N.
672 +* Exposes all pins from the PB05-L Type-C connector.
673 +
674 +
675 +The following diagram shows the pin mapping between PB05 and the E2 Cable.
676 +
679 679  [[image:image-20250303134914-1.png||height="320" width="456"]]
680 680  
681 681  
... ... @@ -682,42 +682,45 @@
682 682  = 3.  Configure PB05-L via AT command or LoRaWAN downlink =
683 683  
684 684  
685 -Users can configure PB05-L via AT Command or LoRaWAN Downlink.
683 +You can configure PB05-L via AT Command or LoRaWAN Downlink command.
686 686  
687 -* AT Command Connection:
685 +* **AT Command Connection: **
688 688  
689 689  [[image:image-20250303141745-4.jpeg||height="489" width="505"]]
690 690  
691 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html||style="background-color: rgb(255, 255, 255);"]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for PB05-L. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(%%)) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again.
692 692  
693 693  (((
694 -Input password and ATZ to activate PB05-L, as shown below:
691 +On a PC, you need to set the serial tool (such as [[PuTTY>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]] or SecureCRT) to a baud rate of **9600** to access the serial console for the PB05-L.
695 695  
693 +AT commands are disabled by default and require entering a password (default: **123456**) to activate them. The AT command input timeout is 5 minutes; after this period, the user must enter the password again.
694 +
695 +Enter the password and ATZ to activate the PB05-L, as shown below:
696 +
697 +
696 696  [[image:image-20250303114409-8.png]]
697 697  
698 698  
699 699  )))
700 700  
701 -* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
703 +* LoRaWAN Downlink instruction for different platforms can be found here: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
702 702  
703 -There are two kinds of commands to configure PB05-L, they are:
704 704  
705 -* (% style="color:#4f81bd" %)**General Commands:**
706 +(((
707 +There are two types of commands to configure the PB05-L:
706 706  
707 -These commands are to configure:
709 +**General Commands**
708 708  
709 -* General system settings like: uplink interval.
711 +These commands configure:
710 710  
711 -* LoRaWAN protocol & radio-related commands.
713 +* General system settings, such as the uplink interval.
714 +* LoRaWAN protocol and radio-related settings.
712 712  
713 -They are the same for all Dragino Devices which supports DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
716 +These commands are the same for all Dragino devices that support the DLWS-005 LoRaWAN stack (**Note~*~***). They can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]].
714 714  
718 +**Commands Specifically Designed for PB05-L**
715 715  
716 -* (% style="color:#4f81bd" %)**Commands special design for PB05-L**
720 +These commands are only valid for the PB05-L, as listed below:
717 717  
718 -These commands are only valid for PB05-L, as below:
719 -
720 -(((
721 721  
722 722  )))
723 723  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0