Changes for page PB05-L -- LoRaWAN Button User Manual
Last modified by Dilisi S on 2025/04/03 15:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -47,7 +47,6 @@ 47 47 * Supports 2 × AA LR6 batteries 48 48 * IP52-rated for dust and water resistance 49 49 50 - 51 51 == 1.3 Power Consumption == 52 52 53 53 ... ... @@ -54,7 +54,6 @@ 54 54 * **Idle:** 5 µA 55 55 * **Transmit:** Max 110 mA 56 56 57 - 58 58 == 1.4 Storage & Operation Temperature == 59 59 60 60 ... ... @@ -71,7 +71,6 @@ 71 71 * Smart Cities 72 72 * Smart Factory 73 73 74 - 75 75 See **Use Cases** for more information. 76 76 77 77 ... ... @@ -186,7 +186,6 @@ 186 186 * **Valid Sensor Value**: Use FPort=2 187 187 * **Other Status / Control Commands**: Use an FPort other than 2. 188 188 189 - 190 190 === 2.4.1 Uplink FPORT~=5, Device Status === 191 191 192 192 ... ... @@ -221,7 +221,6 @@ 221 221 * 0x09: AS923-2 222 222 * 0x0a: AS923-3 223 223 224 - 225 225 (% style="color:#4472c4" %)**Sub-Band**(%%): Value 0x00 ~~ 0x08 (only for CN470, AU915,US915. For others, it's 0x00) 226 226 227 227 (% style="color:#4472c4" %)**BAT**(%%): Shows the battery voltage for PB05-L. ... ... @@ -606,45 +606,49 @@ 606 606 607 607 (% style="display:none" %) (%%) (% style="display:none" %) 608 608 609 -== 2.7 Button == 604 +== 2.7 Buttons == 610 610 611 611 612 -* ACT button 607 +* **ACT button** 613 613 614 -Long press th isbuttonPB05-Lwillreset and join network again.609 +Long press the ACT button to reset the device and allow it to join network again. 615 615 616 616 [[image:image-20250303110613-4.jpeg||height="198" width="472"]] 617 617 618 -* Alarm button 613 +* **Alarm buttons** 619 619 620 - The PB05-Lhasfive alarm buttons.615 +When you press an alarm button, the PB05-L immediately uplinks data. The alarm flag is set to 'TRUE,' and the corresponding button status is 'Yes'. 621 621 622 -When you press one of the alarm buttons, the PB05-L will immediately uplink data, and the alarm flag is "TRUE", and the corresponding button is "Yes". 623 - 624 624 [[image:image-20250303111505-5.jpeg||height="252" width="374"]](% style="display:none" %) 625 625 626 626 627 -== 2.8 LED Indicator == 620 +== 2.8 LED Indicators == 628 628 629 629 630 630 ((( 631 -The PB05-L has a triple color LED which for easy showing different stage. 624 +The** PB05-L** has a **tri-color LED** for easily indicating different stages. 625 + 626 +Hold the **ACT** button until the green light turns on to reset the device. The green LED will flash as the node restarts, the blue LED will flash once when requesting network access, and the green LED will remain on for 5 seconds after successful network access. 632 632 ))) 633 633 634 -Hold the ACT green light to rest, then the green flashing node restarts, the blue flashing once upon request for network access, and the green constant light for 5 seconds after successful network access 635 - 636 636 ((( 637 -(% style="color:#037691" %)**In a normal working state**: 638 -))) 630 +**In a normal working state:** 639 639 640 -* When the node is restarted, hold the ACT (% style="color:green" %)**GREEN**(%%) lights up , then the (% style="color:green" %)**GREEN**(%%) flashing node restarts.The (% style="color:blue" %)**BLUE**(%%) flashing once upon request for network access, and the (% style="color:green" %)**GREEN**(%%) constant light for 5 seconds after successful network access. 641 -* During OTAA Join: 642 -** **For each Join Request uplink:** the (% style="color:green" %)**GREEN LED** (%%)will blink once. 643 -** **Once Join Successful:** the (% style="color:green" %)**GREEN LED**(%%) will be solid on for 5 seconds. 644 -* After joined, for each uplink, the (% style="color:blue" %)**BLUE LED**(%%) or (% style="color:green" %)**GREEN LED** (%%)will blink once. 645 -* Press the alarm button,The (% style="color:red" %)**RED**(%%) flashes until the node receives the ACK from the platform and the (% style="color:blue" %)**BLUE**(%%) light stays 5s. 632 +* When the node restarts, hold the ACT button until the GREEN LED lights up. The GREEN LED will flash as the node restarts. 633 +* The BLUE LED will flash once upon requesting network access. 634 +* The GREEN LED will remain on for 5 seconds after successful network access. 646 646 647 -((( 636 +**During OTAA Join:** 637 + 638 +* For each Join Request uplink, the GREEN LED will blink once. 639 +* Once the Join is successful, the GREEN LED will remain on for 5 seconds. 640 +* After joining, for each uplink, either the BLUE or GREEN LED will blink once. 641 + 642 +**Alarm Button Press:** 643 + 644 +* When an alarm button is pressed, the RED LED will flash until the node receives an ACK from the platform. 645 +* Once the ACK is received, the BLUE LED will stay on for 5 seconds. 646 + 648 648 649 649 ))) 650 650 ... ... @@ -651,31 +651,30 @@ 651 651 == 2.9 Buzzer == 652 652 653 653 654 -The PB05 has** andusers can turn on or offboth soundsby using653 +The PB05 has a **button sound** and an **ACK sound**, both of which users can turn on or off using [[AT+SOUND>>||anchor="H3.3A0SetbuttonsoundandACKsound"]]. 655 655 656 -* (% style="color:#4f81bd" %)**Button sound**(%%)** **is the music produced by the node after the alarm button is pressed. 655 +* (% style="color:#4f81bd" %)**Button sound**(%%) is the tone played by the node after an alarm button is pressed. 656 +You can use [[AT+OPTION>>||anchor="H3.4A0Setbuzzermusictype2807E429"]] to set different button sounds. 657 +* (% style="color:#4f81bd" %)**ACK sound**(%%) is the notification tone played when the node receives an ACK. 657 657 658 - Users can use[[ AT+OPTION>>||anchor="H3.4A0Setbuzzermusictype2807E429"]] to set different button sounds. 659 659 660 -* (% style="color:#4f81bd" %)**ACK sound **(%%)is the notification tone that the node receives ACK. 661 - 662 662 == 2.10 E2 Extension Cable == 663 663 664 664 665 665 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220619092222-1.png?width=188&height=182&rev=1.1||alt="image-20220619092222-1.png"]][[image:image-20250303135532-3.jpeg||height="184" width="234"]] 666 666 667 -**1m long breakout cable for PB05-L. Features:** 668 668 669 -* ((( 670 -Use for AT Command, works for both LHT52/LHT65N/PB05-L. 671 -))) 672 -* ((( 673 -Update firmware for PB05-L, works for both LHT52/LHT65N/PB05-L. 674 -))) 675 -* ((( 676 -Exposed All pins from the PB05-L Type-C connector 677 -))) 666 +**1m Long Breakout Cable for PB05-L** 678 678 668 +**Features:** 669 + 670 +* Used for AT commands; compatible with LHT52, LHT65N, and PB05-L. 671 +* Supports firmware updates for PB05-L; also works with LHT52 and LHT65N. 672 +* Exposes all pins from the PB05-L Type-C connector. 673 + 674 + 675 +The following diagram shows the pin mapping between PB05 and the E2 Cable. 676 + 679 679 [[image:image-20250303134914-1.png||height="320" width="456"]] 680 680 681 681 ... ... @@ -682,42 +682,45 @@ 682 682 = 3. Configure PB05-L via AT command or LoRaWAN downlink = 683 683 684 684 685 - Userscan configure PB05-L via AT Command or LoRaWAN Downlink.683 +You can configure PB05-L via AT Command or LoRaWAN Downlink command. 686 686 687 -* AT Command Connection: 685 +* **AT Command Connection: ** 688 688 689 689 [[image:image-20250303141745-4.jpeg||height="489" width="505"]] 690 690 691 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html||style="background-color: rgb(255, 255, 255);"]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for PB05-L. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(%%)) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. 692 692 693 693 ((( 694 - InputpasswordandATZto activatePB05-L,asownbelow:691 +On a PC, you need to set the serial tool (such as [[PuTTY>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]] or SecureCRT) to a baud rate of **9600** to access the serial console for the PB05-L. 695 695 693 +AT commands are disabled by default and require entering a password (default: **123456**) to activate them. The AT command input timeout is 5 minutes; after this period, the user must enter the password again. 694 + 695 +Enter the password and ATZ to activate the PB05-L, as shown below: 696 + 697 + 696 696 [[image:image-20250303114409-8.png]] 697 697 698 698 699 699 ))) 700 700 701 -* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]] 703 +* LoRaWAN Downlink instruction for different platforms can be found here: [[IoT LoRaWAN Server>>doc:Main.WebHome]] 702 702 703 -There are two kinds of commands to configure PB05-L, they are: 704 704 705 -* (% style="color:#4f81bd" %)**General Commands:** 706 +((( 707 +There are two types of commands to configure the PB05-L: 706 706 707 - Thesecommandsare to configure:709 +**General Commands** 708 708 709 - * Generalsystemsettingslike: uplinkinterval.711 +These commands configure: 710 710 711 -* LoRaWAN protocol & radio-related commands. 713 +* General system settings, such as the uplink interval. 714 +* LoRaWAN protocol and radio-related settings. 712 712 713 -The yare the same for all DraginoDeviceswhichsupportsDLWS-005 LoRaWANStack(Note~*~*). Thesecommandscanbe found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]716 +These commands are the same for all Dragino devices that support the DLWS-005 LoRaWAN stack (**Note~*~***). They can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]. 714 714 718 +**Commands Specifically Designed for PB05-L** 715 715 716 - * (%style="color:#4f81bd" %)**Commandsspecialdesignfor PB05-L**720 +These commands are only valid for the PB05-L, as listed below: 717 717 718 -These commands are only valid for PB05-L, as below: 719 - 720 -((( 721 721 722 722 ))) 723 723