Wiki source code of How to set the transmit time interval -- LoRaWAN End node
Last modified by Bei Jinggeng on 2022/11/10 14:31
Hide last authors
author | version | line-number | content |
---|---|---|---|
14.3 | 1 | **~ Table of Contents:** | |
1.1 | 2 | ||
14.3 | 3 | {{toc/}} | |
4 | |||
14.4 | 5 | ||
6 | |||
7 | |||
1.2 | 8 | = 1. Introduction = | |
1.1 | 9 | ||
14.3 | 10 | ||
9.2 | 11 | This chapter describes how to set Transmit Time Interval. | |
1.1 | 12 | ||
13.2 | 13 | ||
9.2 | 14 | = 2. Downlink Payload = | |
1.1 | 15 | ||
14.3 | 16 | ||
1.2 | 17 | TDC can be controlled by Downlink Payload. | |
1.1 | 18 | ||
9.3 | 19 | ((( | |
14.3 | 20 | **For example**: AT+TDC=0x258=600s ** ; Payload: **01 00 02 58 TDC=600s The time interval is represented by hexadecimal conversion to decimal. | |
9.3 | 21 | ))) | |
1.1 | 22 | ||
13.2 | 23 | [[image:image-20220527085044-1.png]] | |
1.1 | 24 | ||
25 | |||
14.3 | 26 | If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), 3C (HEX) = 60 (decimal),while type code is 01. | |
2.1 | 27 | ||
14.3 | 28 | **Payload: **01 00 00 1E TDC=30s Payload: 01 00 00 3C TDC=60s | |
1.1 | 29 | ||
30 | |||
18.1 | 31 | Example Downlink payload setting in TTN: | |
13.2 | 32 | ||
18.1 | 33 | [[image:image-20221110143023-2.png||height="632" width="808"]] | |
34 | |||
35 | |||
36 | |||
14.3 | 37 | = 3. Downlink Method = | |
1.1 | 38 | ||