3 = 1. Introduction =
4
5 This chapter describes how to set Transmit Time Interval for [[Dragino Sensors>>Dragino Sensors||anchor="End Device AT Commands and Downlink Command/#H4.1ChangeUplinkInterval"]].
6
7 = 2. via AT Command through UART interface =
8
9
10
11 = 3. via LoRaWAN Downlink =
12
13 TDC can be controlled by Downlink Payload.
14
15 (((
16 For example: AT+TDC=0x258=600s Payload: 01 00 02 58 TDC=600s The time interval is represented by hexadecimal conversion to decimal.
17 )))
18
19 [[image:https://wiki.dragino.com/images/8/8e/TDC.png||alt="TDC.png" height="173" width="850"]]
20
21 (((
22
23 )))
24
25 (((
26 If the payload=0100003C, it means set the END Node’s TDC to 0x00003C=60(S), 3C (HEX) = 60 (decimal),while type code is 01.
27 )))
28
29 (((
30 Payload: 01 00 00 1E TDC=30s Payload: 01 00 00 3C TDC=60s
31 )))
32
33 [[image:image-20220512084801-1.png]]
34
35 = 3. Downlink Method =
36
37 See use note for different serves [[Servers Note>>http://8.211.40.43:8080/xwiki/bin/view/Main/]]