3 = 1. Introduction =
4
5 This chapter describes how to set Transmit Time Interval.
6
7
8 = 2. Downlink Payload =
9
10 TDC can be controlled by Downlink Payload.
11
12 (((
13 **For example**: AT+TDC=0x258=600s Payload: 01 00 02 58 TDC=600s The time interval is represented by hexadecimal conversion to decimal.
14 )))
15
16 [[image:image-20220527085044-1.png]]
17
18
19 If the payload=0100003C, it means set the END Node’s TDC to 0x00003C=60(S), 3C (HEX) = 60 (decimal),while type code is 01.
20
21 Payload: 01 00 00 1E TDC=30s Payload: 01 00 00 3C TDC=60s
22
23 [[image:image-20220527085157-3.png]]
24
25
26 == 3. Downlink Method ==