Changes for page How to set the transmit time interval -- LoRaWAN End node
Last modified by Bei Jinggeng on 2022/11/10 14:31
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -2,23 +2,36 @@ 2 2 3 3 = 1. Introduction = 4 4 5 -This chapter describes how to set Transmit Time Interval. 5 +This chapter describes how to set Transmit Time Interval for [[label>>End Device AT Commands and Downlink Command/||anchor=#H4.1ChangeUplinkInterval]]. 6 6 7 -= 2. Downlink Payload =7 += 2. via AT Command through UART interface = 8 8 9 + 10 + 11 += 3. via LoRaWAN Downlink = 12 + 9 9 TDC can be controlled by Downlink Payload. 10 10 15 +((( 11 11 For example: AT+TDC=0x258=600s Payload: 01 00 02 58 TDC=600s The time interval is represented by hexadecimal conversion to decimal. 17 +))) 12 12 13 13 [[image:https://wiki.dragino.com/images/8/8e/TDC.png||alt="TDC.png" height="173" width="850"]] 14 14 21 +((( 22 + 23 +))) 15 15 25 +((( 16 16 If the payload=0100003C, it means set the END Node’s TDC to 0x00003C=60(S), 3C (HEX) = 60 (decimal),while type code is 01. 27 +))) 17 17 29 +((( 18 18 Payload: 01 00 00 1E TDC=30s Payload: 01 00 00 3C TDC=60s 31 +))) 19 19 20 -[[image: https://wiki.dragino.com/images/3/38/Downlink_playload_TDC.png||alt="Downlink playload TDC.png" height="304" width="910"]]33 +[[image:image-20220512084801-1.png]] 21 21 22 -= =3. Downlink Method ==35 += 3. Downlink Method = 23 23 24 24 See use note for different serves [[Servers Note>>http://8.211.40.43:8080/xwiki/bin/view/Main/]]