9
10 1. LoRaWAN Gateway model: [[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]]
11 1. Firmware version since : [[lgw~~-~~-build-v5.4.1644658774>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LIG16/Firmware/Release/]]
12
13
14 = 2.  Introduction =
15
16
17 (((
18 By default, the LoRaWAN gateway cannot receive LoRa Packet, If the user needs to receive the raw LoRa Packet, the user can modify the file.
19 )))
20
21 (((
22 Here are two ways to modify the received raw LoRa package.
23
24
25 )))
26
27 == 2.1  Method 1: ==
28
29
30 (((
31 (% style="color:blue" %)**root@dragino-1d178c:~~# vim /usr/bin/generate-config.sh**
32 )))
33
34 (% class="box" %)
35 (((
36 (((
37 (((
38 gen_cus_cfg() {
39 json_init
40 json_add_object SX130x_conf
41 json_add_string "spidev_path" "/dev/spidev0.0"
42 json_add_boolean "full_duplex" 0
43 json_add_boolean "lorawan_public" 0 ~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--> "1" proves receive LoRaWAN Packet,"0" proves receive non-LoRaWan Packet
44 json_add_int "clksrc" "1"
45 json_add_string "clksrc_desc" "radio_1 provides clock to concentrator"
46 json_add_int "antenna_gain" "0"
47 json_add_string "antenna_gain_desc" "antenna gain, in dBi"
48 )))
49 )))
50 )))
51
52 (((
53
54
55 (% style="color:blue" %)**root@dragino-1d178c:~~# vim /etc/lora/global_conf.json**
56 )))
57
58 (% class="box" %)
59 (((
60 (((
61 (((
62 {
63 "SX130x_conf": {
64 "spidev_path": "/dev/spidev0.0",
65 "full_duplex": false,
66 "lorawan_public": false,  ~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--> "true" proves receive LoRaWAN Packet,"false" proves receive non-LoRaWan Packet
67 "clksrc": 1,
68 "clksrc_desc": "radio_1 provides clock to concentrator for most devices except MultiTech. For MultiTech set to 0.",
69 "antenna_gain": 0,
70 "antenna_gain_desc": "antenna gain, in dBi",
71 "radio_0": {
72 )))
73 )))
74 )))
75
76 (((
77 and run (% style="color:#037691" %)**root@dragino-1d178c:~~# fwd**
78
79
80 )))
81
82 == 2.2  Method 2: ==
83
84
85 (((
86 Modify /etc/lora/cfg-$chip/"frequency"-global_conf.json
87 )))
88
89 (((
90 view chip name : cat /tmp/iot/chip
91 )))
92
93 (((
94 Restart the device after the modification
95 )))
96
97 (((
98 [[image:image-20220527172224-1.png]]
99 )))
100
101 (((
102 modify /etc/lora/cfg-$chip/"frequency"-global_conf.json
103
104
105 )))
106
107 (((
108 (% style="color:red" %)**Note : User need to do that connect gateway command line via ssh.**
109
110
111 )))
112
113 (((
114 (((
115 [[image:image-20220527172304-2.png]]
116 )))
117 )))
118
119 (((
120 Checking LoRaWAN Gateway Log
121
122
123 )))
124
125 (((
126 Command line input (% style="color:#037691" %) **logread -f**
127 )))
128
129 (((
130 (((
131
132 )))
133 )))
134
135 (((
136 **Decoding verifies that the packet is correct**
137
138 [[image:image-20220722161946-1.png]]
139 )))
140
141
142 Checking LoRa Packet
143
144
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0