7 = 1. Overview =
8
9
10 There are some new models of Dragino sensors support OTA update via Private LoRa Protocol, (Even the sensor runs LoRaWAN protocol by default)
11
12
13 = 2. Support Models =
14
15
16 Here list the models that support OTA Update.
17
18
19 {{velocity}}
20 $xwiki.ssfx.use("js/xwiki/table/table.css")
21 $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
22 {{/velocity}}
23
24 (% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f2f2f2; width:670px" %)
25 (% class="sortHeader" %)|=(% style="width: 193px;background-color:#D9E2F3" %)Models|=(% style="width: 222px;background-color:#D9E2F3" %)Firmware Version|=(% style="width: 251px;background-color:#D9E2F3" %)Comments
26 |(% style="width:193px" %)PS-LB, SDI-12-LB|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
27 |(% style="width:193px" %)SN50v3-LB|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
28 |(% style="width:193px" %)D20-LB/D20S/LB/D22-LB/D23-LB|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
29 |(% style="width:193px" %)(((
30 LHT65N-PIR,LHT65N-E31F
31 )))|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
32 |(% style="width:193px" %)S31-LB, S31B-LB|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
33
34
35 = 3. How to do OTA update =
36
37 == 3.1 Required Components ==
38
39
40 * Hardware: [[LA66 USB>>doc:Main.User Manual for LoRaWAN End Nodes.LA66 USB LoRaWAN Adapter User Manual.WebHome]] with [[OTA_firmware>>https://www.dropbox.com/sh/4qnjreg1esxu16i/AADbRjW_tuBP3IIkmf11nSoma?dl=0]] installed.
41
42 * Software: [[OTA_Tool>>https://www.dropbox.com/sh/4qnjreg1esxu16i/AADbRjW_tuBP3IIkmf11nSoma?dl=0]]. Only support Windows now
43
44 [[image:image-20230513120722-2.png||height="409" width="866"]]
45
46
47 (% class="wikigeneratedid" %)
48 == 3.2 Video Instruction ==
49
50
51 (% class="wikigeneratedid" %)
52 Instruction ~-~- OTA Upgrade Firmware (via LoRa) of LoRaWAN Sensors**: [[https:~~/~~/youtu.be/SSvOqvBrwGg>>https://youtu.be/SSvOqvBrwGg]]**
53
54 (% class="wikigeneratedid" %)
55 == ==
56
57 == 3.3 Update Steps ==
58
59
60 === (% style="color:blue" %)**Step1 :**(%%) Plug LA66 USB to PC and run OTA_Tool. ===
61
62
63 [[image:image-20230114172703-1.png]]
64
65
66 === (% style="color:blue" %)**Step2:**(%%) Set up OTA Tool ===
67
68
69 * (% style="color:blue" %)**DevEUI**(%%): Input Dev EUI of your sensor
70
71 * (% style="color:blue" %)**Password**(%%): Passord of your sensor
72
73 * (% style="color:blue" %)**Port**(%%): Com port of LA66 USB
74
75 * (% style="color:blue" %)**LoRa_Freq**(%%): Choose the shipped frequency band of your sensor.
76
77 * (% style="color:blue" %)**Upload_File**(%%): The firmware to be upload to the sensor. make sure the firmware is with surfix _without_bootloader. For example: LHT65N_EU868_v1.5_without_bootloader.
78
79 * (% style="color:blue" %)**EUI File**(%%): If customer has lots of sensors. He can also import the Dev EUI files and use droplist to choose the sensor to update. Format is as below:
80
81 [[image:image-20230114174640-3.png||height="130" width="1169"]]
82
83
84 === (% style="color:blue" %)**Step3:**(%%) Press Start in OTA Tool and then Press Reset button to restart LA66 USB ===
85
86
87 After press reset button, LA66 USB will restart and broadcast update process with the Dev EUI and Password.
88
89
90 === (% style="color:blue" %)**Step4:** (%%)Press reset button on the end node, or re-activate the end node. ===
91
92
93 In every reboot/ reactivate, the end node will check if there is update request. If end node gets the update request from LA66. End node will check if the Dev EUI and Password match. If match, End node will establish connection with LA66 USB for OTA update.
94
95
96 === (% style="color:blue" %)**Step5:**(%%) Check result. ===
97
98
99 Below shows the update successul result.
100
101 [[image:image-20230114174134-2.png]]
102
103
104 = 4. FAQ =
105
106 == 4.1 Can i use other devices to connect to PC if i don't have LA66 USB? ==
107
108
109 If user doesn't have LA66 USB Adapter, they can still use other Dragino Device to connect to PC for OTA update.
110
111 (% style="color:blue" %)**Steps:**
112
113 * Find the suitable mode which base on LA66 chip ( All LoRaWAN model with LB or LS suffix , such as SN50v3-LB)
114
115 * Update the LA66 USB OTA firmware to the device.
116
117 * Connect the device to PC via UART interface.
118
119 * Make sure power off or update the firmware back to original firmware , because the LA66 USB OTA fimware is not low power consumption firmware. it will consume the battery very fast.
120
121
122 == 4.2 Where to find OTA Password? ==
123
124
125 Each device has a shipped label with OTA Password which is 16 chars. like below. If user don't find this, please send us a photo for the device with Dev EUI to [[support@dragino.com>>mailto:support@dragino.com]] . and we will search the password for you.
126
127 [[image:image-20230519102907-2.png||height="286" width="580"]]
128
129
130 == 4.3 How about if i upgrade a crashed firmware via OTA update? ==
131
132
133 OTA update is done via Bootloader and only change the firmware partition. So update a crash firmware via OTA update won't destroy bootloader and user can use OTA method to update again.
134
135 (% style="color:red" %)**Here are notice:**
136
137 ~1. OTA update frequency depend on the firmware frequency. If there is no frequency in the firmware. Bootloader will use EU868 as default frequency.
138
139 2. OTA update require a reset or reactivate action. If the crash firmware doesn't have them work, user need to manuall push the physic reset button on the PCB or power off/on device.
140
141
142 = 5. OTA Tool Known Bug: =
143
144
145 ~1. If user click "(% style="color:blue" %)**Start**"(%%) but there is issue during update. User may need to close and open the tool again.