Hide last authors
Xiaoling 1.3 1 = 1. Introduction =
Xiaoling 1.1 2
Xiaoling 1.3 3 This chapter describe the checklist for not able to access to AT Command in Dragino LoRaWAN End Node base on STM32 chip.
Xiaoling 1.1 4
Xiaoling 1.3 5 = 2. Not able to send AT Command =
Xiaoling 1.1 6
Xiaoling 1.3 7 * Do you use a USB to TTL Converter? If you use RS232 converter, it won't work
8 * Can you see the output from console.
9 * Do you use the correct baudrate:
Xiaoling 1.1 10
Xiaoling 1.4 11 (% class="box" %)
12 (((
13 ~** Baudrate: 9600
14 ~** Data bits: 8
15 ~** Stop bits: 1
16 ~** Parity: None
17 ~** Flow control: None
18 )))
Xiaoling 1.1 19
Xiaoling 1.3 20 * Did you have the hardware RXD pin connected correctly according to the user manual?
21 * Did you add the **ENTER** and **NEW LINE** after press send. Some serial utility doesn't add them by default. Below is an example for adding new line:
Xiaoling 1.1 22
Xiaoling 1.3 23 [[image:https://wiki.dragino.com/images/thumb/5/5c/UART_access_1.png/600px-UART_access_1.png||height="419" width="600"]]
Xiaoling 1.1 24
Xiaoling 1.3 25 Add a new line in some software
Xiaoling 1.1 26
27
Xiaoling 1.3 28 = 3. If you still not able to fix this issue =
Xiaoling 1.1 29
Xiaoling 1.3 30 please send us below info at support@dragino.com
Xiaoling 1.1 31
Xiaoling 1.3 32 * Screen shot for your serial utility baud rate settings.
33 * Screen shot of your serial console.
34 * A photo shows clearly how you use USB-TTL adapter connect to the device.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved