... ... @@ -34,7 +34,7 @@
34 34  * **Working environment:**
35 35  ** Ambient Temperature: 0–60°C
36 36  ** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
37 -** ECK200 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments
37 +** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments
38 38  * **IP Rated**: IP68
39 39  * **Max Pressure**: 0.6MPa
40 40  
... ... @@ -52,7 +52,7 @@
52 52  
53 53  == 1.4 Mechinical Drawing ==
54 54  
55 - ECK1 and ECK10  EC200
55 + ECK1 and ECK10  ECK200
56 56  
57 57  
58 58  [[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]]
... ... @@ -212,28 +212,8 @@
212 212  **For example**, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686,  K=1, EC: 686uS/cm,temperature: 35.6℃ Convert the returned data to decimal and divide by 10.
213 213  
214 214  
215 -EC200
215 +ECK200
216 216  
217 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:534.333px" %)
218 -|=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 74px; background-color: rgb(79, 129, 189); color: white;" %)Register Address|=(% style="width: 94px; background-color: rgb(79, 129, 189); color: white;" %)Register length|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 77px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high
219 -|(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:74px" %)0X00 0X00|(% style="width:94px" %)0X00 0X04|(% style="width:72px" %)(((
220 -0XC5
221 -)))|(% style="width:77px" %)0XC8
222 -
223 -**response:**
224 -
225 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:534.333px" %)
226 -|=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 74px; background-color: rgb(79, 129, 189); color: white;" %)Number of valid bytes|=(% style="width: 94px; background-color: rgb(79, 129, 189); color: white;" %)Register contents|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 77px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high
227 -|(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:74px" %)0X08|(% style="width:94px" %)(((
228 -0X00 0X00  0X00 0X000X00 0X00
229 -)))|(% style="width:72px" %)(((
230 -0XC5
231 -)))|(% style="width:77px" %)0XC8
232 -
233 -
234 -
235 -
236 -
237 237  === 1.7.5 Calibration Method ===
238 238  
239 239  ECK1 and ECK10.0
... ... @@ -282,7 +282,7 @@
282 282  
283 283  
284 284  
285 -EC200
265 +ECK200.0
286 286  
287 287  For the device with address 01, use 1413uS/cm standard solution to calibrate the first point. Send frame: 1413. Convert hexadecimal to 585. Write 0001, 00 00, 0585 to 0x0120, 0x0121, 0x0122 respectively.
288 288