Changes for page Water Quality Sensors

Last modified by Karry Zhuang on 2025/07/18 16:37

From version 72.18
edited by Karry Zhuang
on 2025/07/16 09:58
Change comment: There is no comment for this version
To version 72.13
edited by Karry Zhuang
on 2025/07/16 09:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -113,10 +113,7 @@
113 113  RS485 signal (K1 default address 0x12; K10 default address 0x11):
114 114  Standard Modbus-RTU protocol, baud rate: 9600; check bit: none; data bit: 8; stop bit: 1
115 115  
116 -**The following commands are by default for ECK1/ECK10. Please note that EC200 has different commands.**
117 117  
118 -(% style="color:red" %)**ery.**
119 -
120 120  === 1.7.1 Query address ===
121 121  
122 122  
... ... @@ -230,17 +230,13 @@
230 230  |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:74px" %)0X08|(% style="width:94px" %)(((
231 231  0X00 0X00  0X1E 0XEF 0X01 0X14 0X00 0X2B
232 232  )))|(% style="width:72px" %)(((
233 -0X42
234 -)))|(% style="width:77px" %)0X59
230 +0XC5
231 +)))|(% style="width:77px" %)0XC8
235 235  
236 -Conductivity calculation: 0X1EEF=7919=>Conductivity=7919μS/cm
237 -Temperature calculation: 0X0114=276=>Temperature=27.6℃
238 -Salinity calculation: 0X002b=43=>Salinity=4.3PSU
239 239  
240 240  
241 241  
242 242  
243 -
244 244  === 1.7.5 Calibration Method ===
245 245  
246 246  ECK1 and ECK10.0