Changes for page Water Quality Sensors

Last modified by Karry Zhuang on 2025/07/18 16:37

From version 72.17
edited by Karry Zhuang
on 2025/07/16 09:57
Change comment: There is no comment for this version
To version 72.12
edited by Karry Zhuang
on 2025/07/16 09:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -116,7 +116,6 @@
116 116  
117 117  === 1.7.1 Query address ===
118 118  
119 -ECK1/ECK10
120 120  
121 121  **send:**
122 122  
... ... @@ -226,19 +226,15 @@
226 226  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:534.333px" %)
227 227  |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 74px; background-color: rgb(79, 129, 189); color: white;" %)Number of valid bytes|=(% style="width: 94px; background-color: rgb(79, 129, 189); color: white;" %)Register contents|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 77px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high
228 228  |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:74px" %)0X08|(% style="width:94px" %)(((
229 -0X00 0X00  0X1E 0XEF 0X01 0X14 0X00 0X2B
228 +0X00 0X00  0X1E 0XEF 0X01 0X14 0X00 0X00
230 230  )))|(% style="width:72px" %)(((
231 -0X42
232 -)))|(% style="width:77px" %)0X59
230 +0XC5
231 +)))|(% style="width:77px" %)0XC8
233 233  
234 -Conductivity calculation: 0X1EEF=7919=>Conductivity=7919μS/cm
235 -Temperature calculation: 0X0114=276=>Temperature=27.6℃
236 -Salinity calculation: 0X002b=43=>Salinity=4.3PSU
237 237  
238 238  
239 239  
240 240  
241 -
242 242  === 1.7.5 Calibration Method ===
243 243  