Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/25 09:38
From version 72.1
edited by Karry Zhuang
on 2025/07/16 09:22
on 2025/07/16 09:22
Change comment:
There is no comment for this version
To version 70.1
edited by Karry Zhuang
on 2025/07/15 19:14
on 2025/07/15 19:14
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -5,7 +5,7 @@ 5 5 6 6 7 7 8 -= 1. DR-EC Water EC Probe = 8 += 1. DR-ECK Water EC Probe = 9 9 10 10 == 1.1 Specification: == 11 11 ... ... @@ -17,25 +17,20 @@ 17 17 * **Interface**: RS485. 9600 Baud Rate 18 18 19 19 * **EC Range & Resolution:** 20 -** **ECK1.0 :** 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 21 -** **ECK10.0 : **10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 22 -** **EC200 : **1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 20 +** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 +** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 +** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 +** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 25 + 23 23 * **EC Accuracy**: ±1% FS 24 -* **Salinity measurement range** 25 -** **EC200 :**0~~70PSU Resolution: 0.1PSU 26 -* **Temperature measurement range** 27 -** **ECK1/ECK10:**-20~~+60℃; Resolution: 0.1℃ 28 -** **EC200 :**-5~~+80℃; Resolution: 0.1℃ 29 29 * **Temperature Accuracy: **±0.5 °C 30 -* **Temperature compensation range** 31 -** **ECK1/ECK10:**0~~+60℃ (default compensation temperature 25℃) 32 -** **EC200:**-5~~+80℃ (default compensation temperature 25℃) 33 -* **Temperature compensation coefficient:**Default 0.2 34 34 * **Working environment:** 35 35 ** Ambient Temperature: 0–60°C 36 36 ** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 37 37 ** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 38 38 * **IP Rated**: IP68 33 + 39 39 * **Max Pressure**: 0.6MPa 40 40 41 41 == 1.2 Application for Different Range == ... ... @@ -1052,6 +1052,16 @@ 1052 1052 1053 1053 1054 1054 1050 + 1051 + 1052 + 1053 + 1054 + 1055 + 1056 + 1057 + 1058 + 1059 + 1055 1055 = 7. Water Quality Sensor Datasheet = 1056 1056 1057 1057 * **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**