Changes for page Water Quality Sensors

Last modified by Karry Zhuang on 2025/07/18 16:37

From version 71.8
edited by Karry Zhuang
on 2025/07/16 09:20
Change comment: There is no comment for this version
To version 72.2
edited by Karry Zhuang
on 2025/07/16 09:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -17,24 +17,24 @@
17 17  * **Interface**: RS485. 9600 Baud Rate
18 18  
19 19  * **EC Range & Resolution:**
20 -** **ECK1.0** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
21 -** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
22 -** **EC200.0** : 1 ~~ 200,000 μS/cm  Resolution: 1 μS/cm
20 +** **ECK1.0 :** 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
21 +** **ECK10.0 : **10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
22 +** **EC200 : **1 ~~ 200,000 μS/cm  Resolution: 1 μS/cm
23 23  * **EC Accuracy**: ±1% FS
24 24  * **Salinity measurement range**
25 -** **EC200** :0~~70PSU Resolution: 0.1PSU
25 +** **EC200 :**0~~70PSU Resolution: 0.1PSU
26 26  * **Temperature measurement range**
27 -** **ECK1/ECK10**:-20~~+60℃; Resolution: 0.1℃
28 -** **EC200** :-5~~+80℃; Resolution: 0.1℃
27 +** **ECK1/ECK10:**-20~~+60℃; Resolution: 0.1℃
28 +** **EC200 :**-5~~+80℃; Resolution: 0.1℃
29 29  * **Temperature Accuracy: **±0.5 °C
30 30  * **Temperature compensation range**
31 -** **ECK1/ECK10**:-5~~+80℃ (default compensation temperature 25℃)
32 -** **EC200**:-5~~+80℃ (default compensation temperature 25℃)
33 -*
31 +** **ECK1/ECK10:**0~~+60℃ (default compensation temperature 25℃)
32 +** **EC200:**-5~~+80℃ (default compensation temperature 25℃)
33 +* **Temperature compensation coefficient:**Default 0.2
34 34  * **Working environment:**
35 35  ** Ambient Temperature: 0–60°C
36 36  ** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
37 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments
37 +** ECK200 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments
38 38  * **IP Rated**: IP68
39 39  * **Max Pressure**: 0.6MPa
40 40  
... ... @@ -52,7 +52,7 @@
52 52  
53 53  == 1.4 Mechinical Drawing ==
54 54  
55 - ECK1 and ECK10  ECK200
55 + ECK1 and ECK10  EC200
56 56  
57 57  
58 58  [[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]]
... ... @@ -212,8 +212,10 @@
212 212  **For example**, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686,  K=1, EC: 686uS/cm,temperature: 35.6℃ Convert the returned data to decimal and divide by 10.
213 213  
214 214  
215 -ECK200
215 +EC200
216 216  
217 +
218 +
217 217  === 1.7.5 Calibration Method ===
218 218  
219 219  ECK1 and ECK10.0