Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/25 09:38
From version 71.5
edited by Karry Zhuang
on 2025/07/16 09:18
on 2025/07/16 09:18
Change comment:
There is no comment for this version
To version 72.2
edited by Karry Zhuang
on 2025/07/16 09:25
on 2025/07/16 09:25
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,19 +17,24 @@ 17 17 * **Interface**: RS485. 9600 Baud Rate 18 18 19 19 * **EC Range & Resolution:** 20 -** **ECK1.0** :0 ~~ 2,000 μS/cm Resolution: 1 μS/cm21 -** **ECK10.0 **: 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm22 -** **EC200 .0**: 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm20 +** **ECK1.0 :** 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 21 +** **ECK10.0 : **10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 22 +** **EC200 : **1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 23 23 * **EC Accuracy**: ±1% FS 24 24 * **Salinity measurement range** 25 -** **EC200 **:0~~70PSU Resolution: 0.1PSU25 +** **EC200 :**0~~70PSU Resolution: 0.1PSU 26 26 * **Temperature measurement range** 27 -** **EC200** :-5~~+80℃; Resolution: 0.1℃ 27 +** **ECK1/ECK10:**-20~~+60℃; Resolution: 0.1℃ 28 +** **EC200 :**-5~~+80℃; Resolution: 0.1℃ 28 28 * **Temperature Accuracy: **±0.5 °C 30 +* **Temperature compensation range** 31 +** **ECK1/ECK10:**0~~+60℃ (default compensation temperature 25℃) 32 +** **EC200:**-5~~+80℃ (default compensation temperature 25℃) 33 +* **Temperature compensation coefficient:**Default 0.2 29 29 * **Working environment:** 30 30 ** Ambient Temperature: 0–60°C 31 31 ** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 32 -** ECK200 .0Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments37 +** ECK200 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 33 33 * **IP Rated**: IP68 34 34 * **Max Pressure**: 0.6MPa 35 35 ... ... @@ -47,7 +47,7 @@ 47 47 48 48 == 1.4 Mechinical Drawing == 49 49 50 - ECK1 and ECK10 EC K20055 + ECK1 and ECK10 EC200 51 51 52 52 53 53 [[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] ... ... @@ -207,8 +207,10 @@ 207 207 **For example**, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm,temperature: 35.6℃ Convert the returned data to decimal and divide by 10. 208 208 209 209 210 -EC K200215 +EC200 211 211 217 + 218 + 212 212 === 1.7.5 Calibration Method === 213 213 214 214 ECK1 and ECK10.0