Summary

Details

Page properties
Content
... ... @@ -17,13 +17,20 @@
17 17  * **Interface**: RS485. 9600 Baud Rate
18 18  
19 19  * **EC Range & Resolution:**
20 -** **ECK1.0** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
21 -** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
22 -** **EC200.0** : 1 ~~ 200,000 μS/cm  Resolution: 1 μS/cm
23 -* **Salinity measurement range**
24 -** **EC200** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
20 +** **ECK1.0 :** 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
21 +** **ECK10.0 : **10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
22 +** **EC200 : **1 ~~ 200,000 μS/cm  Resolution: 1 μS/cm
25 25  * **EC Accuracy**: ±1% FS
24 +* **Salinity measurement range**
25 +** **EC200 :**0~~70PSU Resolution: 0.1PSU
26 +* **Temperature measurement range**
27 +** **ECK1/ECK10:**-20~~+60℃; Resolution: 0.1℃
28 +** **EC200 :**-5~~+80℃; Resolution: 0.1℃
26 26  * **Temperature Accuracy: **±0.5 °C
30 +* **Temperature compensation range**
31 +** **ECK1/ECK10:**0~~+60℃ (default compensation temperature 25℃)
32 +** **EC200:**-5~~+80℃ (default compensation temperature 25℃)
33 +* **Temperature compensation coefficient:**Default 0.2
27 27  * **Working environment:**
28 28  ** Ambient Temperature: 0–60°C