Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.karry - Content
-
... ... @@ -21,7 +21,6 @@ 21 21 * **IP Rated**: IP68 22 22 * **Max Pressure**: 0.6MPa 23 23 24 - 25 25 == 1.2 Application for Different Range == 26 26 27 27 [[image:image-20240714173018-1.png]] ... ... @@ -41,4 +41,76 @@ 41 41 == 1.6 Maintain == 42 42 43 43 43 +== 1.7 RS485 Commands == 44 + 45 + 46 +The address of the EC K10 sensor is 11 47 + 48 +The query data command is 11 03 00 00 00 02 C6 9B 49 + 50 +For example, the returned data is 11 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 8B D0. 02 AE is converted to decimal 686, K=10, EC: 6860uS/cm 51 + 52 + 53 +The address of the EC K1 sensor is 12 54 + 55 +The query data command is 12 03 00 00 00 02 C6 A8 56 + 57 +For example, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm. 58 + 59 + 60 += 2. DR-PH01 Water PH Sensor = 61 + 62 +== 2.7 RS485 Commands == 63 + 64 + 65 +The address of the pH sensor is 10 66 + 67 +The query data command is 10 03 00 00 00 01 87 4B. After the query, 7 bytes will be returned. 68 + 69 +For example, the returned data is 10 03 02 (% style="color:red" %)**02 AE**(%%) C4 9B. 70 + 71 +02 AE is the pH value, which is converted into decimal to get 686, and then two decimal places are added to get the actual value. 02 AE means the current pH value is 6.86. 72 + 73 + 74 += 3. DR-ORP1 Water ORP Sensor = 75 + 76 +== 3.7 RS485 Commands == 77 + 78 + 79 +The address of the ORP sensor is 13 80 + 81 +The query data command is 13 03 00 00 00 01 87 78 82 + 83 +For example, the returned data is 13 03 02 (% style="color:red" %)**02 AE**(%%) 80 9B. 84 + 85 +02 AE is the ORP value, converted to decimal, the actual value is 686, 02 AE means the current ORP value is 686mV 86 + 87 + 88 += 4. DR-DO1 Dissolved Oxygen Sensor = 89 + 90 +== 4.7 RS485 Commands == 91 + 92 + 93 +The address of the dissolved oxygen sensor is 14 94 + 95 +The query data command is 14 03 00 14 00 01 C6 CB 96 + 97 +After the query, 7 bytes will be returned. For example, the returned data is 14 03 02 (% style="color:red" %)**03 78**(%%) B5 55. 03 78 is the value of dissolved oxygen. 98 + 99 +Converted to decimal, it is 888. Add two decimal places to get the actual value. 03 78 means the current dissolved oxygen is 8.88mg/L 100 + 101 + 102 += 5. DR-TS1 Water Turbidity Sensor = 103 + 104 +== 5.7 RS485 Commands == 105 + 106 + 107 +The address of the dissolved oxygen sensor is 15 108 + 109 +The query data command is 15 03 00 00 00 01 87 1E 110 + 111 +For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 112 + 113 +02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 114 + 44 44