Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 68.1
edited by Karry Zhuang
on 2025/07/15 18:34
on 2025/07/15 18:34
Change comment:
There is no comment for this version
To version 69.2
edited by Karry Zhuang
on 2025/07/15 19:06
on 2025/07/15 19:06
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -468,8 +468,8 @@ 468 468 Query the data (PH) of the sensor (address 10), host → slave 469 469 470 470 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) 471 -|=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width:68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high472 -|(% style="width:99px" %)0X10|(% style="width:7 2px" %)0X03|(% style="width:64px" %)0X00|(% style="width:68px" %)0X00|(% style="width:70px" %)0X00|(% style="width:72px" %)0X01|(% style="width:56px" %)0X87|(% style="width:56px" %)0X4B471 +|=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 74px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 75px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 472 +|(% style="width:99px" %)0X10|(% style="width:74px" %)0X03|(% style="width:75px" %)0X00|(% style="width:68px" %)0X00|(% style="width:70px" %)0X00|(% style="width:72px" %)0X01|(% style="width:56px" %)0X87|(% style="width:56px" %)0X4B 473 473 474 474 If the sensor receives correctly, the following data will be returned, slave → host 475 475 ... ... @@ -991,9 +991,53 @@ 991 991 992 992 [[image:1752573643879-991.png||height="360" width="343"]] 993 993 994 +== 6.5 Maintenance == 994 994 996 +* The device itself generally does not require daily maintenance. When an obvious fault occurs, please do not open it and repair it yourself, and contact us as soon as possible! 997 +* After using the electrode, please clean the electrode head with clean water and cover it with a protective cover. 998 +* When measuring the device, the measured liquid should flow and the flow rate should be uniform, and there should be no bubbles attached to the measuring end of the device. 999 +* If the electrode diaphragm is attached with dirt and mineral components, the sensitivity will be reduced, and it may not be possible to perform sufficient measurement. Please ensure that the platinum ring is clean. 1000 +* The platinum induction ring of a good residual chlorine electrode should always be kept clean and bright. If the platinum ring of the electrode becomes rough or covered with pollutants after measurement, please clean it according to the following method: (For reference) Inorganic pollution: immerse the electrode in 0.1mol/L dilute hydrochloric acid for 15 minutes, gently wipe the platinum ring of the residual chlorine electrode with a cotton swab, and then wash it with tap water. 1001 +* Organic or oil pollution: immerse the electrode in tap water with a small amount of detergent, such as dishwashing liquid, and thoroughly clean the sensing surface of the electrode sensor. Gently wipe the platinum ring of the electrode with a cotton swab, then rinse with tap water, and the cleaning is complete. If the platinum ring of the electrode has formed an oxide film, please use toothpaste or 1000-grit fine sandpaper to properly polish the sensing surface, and then clean it with tap water. The platinum ring is connected to the glass, so please handle it carefully when polishing. 1002 +The electrode has a service life of about one year, and a new electrode should be replaced in time after aging. 1003 +* Before the cable plug and the device plug are locked, do not put the plug part into water. 995 995 996 996 1006 + 1007 +== 6.6 RS485 Commands == 1008 + 1009 +RS485 signal 1010 +Standard Modbus-RTU protocol, baud rate: 9600; check bit: none; data bit: 8; stop bit: 1 1011 + 1012 + 1013 +== 6.7 Query data == 1014 + 1015 +Example 1: Read the current residual chlorine concentration of the device with address 01 1016 + 1017 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:534.333px" %) 1018 +|=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Register Address|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Register length|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Data length|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 60px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 1019 +|(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:135px" %)0X01 0X00|(% style="width:126px" %)0X00 0X03|(% style="width:85px" %)0X06|(% style="width:1px" %)((( 1020 +0X80 1021 +)))|(% style="width:60px" %)0X3e 1022 + 1023 + 1024 + 1025 + 1026 + 1027 + 1028 + 1029 + 1030 + 1031 + 1032 + 1033 + 1034 + 1035 + 1036 + 1037 + 1038 + 1039 + 1040 + 997 997 = 7. Water Quality Sensor Datasheet = 998 998 999 999 * **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**