Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 63.2
edited by Karry Zhuang
on 2025/07/15 17:51
on 2025/07/15 17:51
Change comment:
There is no comment for this version
To version 68.1
edited by Karry Zhuang
on 2025/07/15 18:34
on 2025/07/15 18:34
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (1 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -948,11 +948,10 @@ 948 948 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 949 949 950 950 951 -= 6. DR- ECKWaterEC Probe =951 += 6. DR-CL Water CL Probe = 952 952 953 953 == 6.1 Specification: == 954 954 955 - 956 956 * **Power Input**: DC7~~30 957 957 958 958 * **Power Consumption** : 0.19W ... ... @@ -960,20 +960,41 @@ 960 960 * **Interface**: RS485. 9600 Baud Rate 961 961 962 962 * **CL Range & Resolution:** 963 -** **CL2ML/CL10ML** : 0.01mg/L 964 964 ** **CL2ML:**0-2mg/L 965 965 ** **CL10ML:**0-10mg/L 964 +** **Resolution:**0.01mg/L 966 966 967 -* ** EC Accuracy**: ±1% FS966 +* **CL Accuracy**: ±5% FS 968 968 * **Temperature Accuracy: **±0.5 °C 969 969 * **Working environment:** 970 -** Ambient Temperature: 0– 60°C971 -** RelativeHumidity:<85% RH(Specifically refers to the cable male and female)972 -** ECK200.0 Continuousmonitoring of cross-section waterquality,aquaculture, sewagetreatment,environmentalprotection, pharmaceuticals, food, tap water, seawater and other high conductivity environments969 +** Ambient Temperature: 0–50°C 970 +** pH:4-9 971 +** Flow rate: 30L/h~~60L/h (flow tank installation) 973 973 * **IP Rated**: IP68 974 974 975 975 * **Max Pressure**: 0.6MPa 976 976 976 +== 6.2 Wiring == 977 977 978 +[[image:image-20240720172548-2.png||height="348" width="571"]] 978 978 980 +== 6.3 Mechinical Drawing == 981 + 982 +[[image:1752573238705-910.png||height="694" width="278"]] 983 + 984 +== 6.4 Installation == 985 + 986 +Flow-through installation: Use the matching flow slot for installation. The device and the flow slot are installed tightly. 987 + 988 +The measuring end is completely immersed in the measured liquid to ensure a steady flow rate without bubbles. 989 + 990 +It is recommended that the flow rate be controlled at 30-60Lh to ensure the accuracy of the test. 991 + 992 +[[image:1752573643879-991.png||height="360" width="343"]] 993 + 994 + 995 + 996 + 997 += 7. Water Quality Sensor Datasheet = 998 + 979 979 * **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
- image-20240720172548-2.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 1.5MB1 +262.2 KB - Content
- 1752573238705-910.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.3 KB - Content
- 1752573643879-991.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +163.2 KB - Content