Changes for page Water Quality Sensors

Last modified by Karry Zhuang on 2025/07/18 16:37

From version 63.1
edited by Karry Zhuang
on 2025/07/15 17:47
Change comment: There is no comment for this version
To version 63.3
edited by Karry Zhuang
on 2025/07/15 17:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -948,7 +948,32 @@
948 948  02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU
949 949  
950 950  
951 -= 6.  Water Quality Sensor Datasheet =
951 += 6. DR-ECK Water EC Probe =
952 952  
953 +== 6.1 Specification: ==
953 953  
955 +
956 +* **Power Input**: DC7~~30
957 +
958 +* **Power Consumption** : 0.19W
959 +
960 +* **Interface**: RS485. 9600 Baud Rate
961 +
962 +* **CL Range & Resolution:**
963 +** **CL2ML:**0-2mg/L
964 +** **CL10ML:**0-10mg/L
965 +** **Resolution:**0.01mg/L
966 +
967 +* **CL Accuracy**: ±5% FS
968 +* **Temperature Accuracy: **±0.5 °C
969 +* **Working environment:**
970 +** Ambient Temperature: 0–50°C
971 +** pH:4-9
972 +** Flow rate: 30L/h~~60L/h (flow tank installation)
973 +* **IP Rated**: IP68
974 +
975 +* **Max Pressure**: 0.6MPa
976 +
977 +
978 +
954 954  * **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**