Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 63.1
edited by Karry Zhuang
on 2025/07/15 17:47
on 2025/07/15 17:47
Change comment:
There is no comment for this version
To version 63.3
edited by Karry Zhuang
on 2025/07/15 17:53
on 2025/07/15 17:53
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -948,7 +948,32 @@ 948 948 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 949 949 950 950 951 -= 6. QualitySensorDatasheet=951 += 6. DR-ECK Water EC Probe = 952 952 953 +== 6.1 Specification: == 953 953 955 + 956 +* **Power Input**: DC7~~30 957 + 958 +* **Power Consumption** : 0.19W 959 + 960 +* **Interface**: RS485. 9600 Baud Rate 961 + 962 +* **CL Range & Resolution:** 963 +** **CL2ML:**0-2mg/L 964 +** **CL10ML:**0-10mg/L 965 +** **Resolution:**0.01mg/L 966 + 967 +* **CL Accuracy**: ±5% FS 968 +* **Temperature Accuracy: **±0.5 °C 969 +* **Working environment:** 970 +** Ambient Temperature: 0–50°C 971 +** pH:4-9 972 +** Flow rate: 30L/h~~60L/h (flow tank installation) 973 +* **IP Rated**: IP68 974 + 975 +* **Max Pressure**: 0.6MPa 976 + 977 + 978 + 954 954 * **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**