955 955  = 6. DR-CL Water Turbidity Sensor =
956 956  
957 -This product is a device for measuring the residual gas concentration in water (hypochlorous acid, hypochlorite concentration). The three-electrode system has the advantages of high measurement accuracy, long working life and no need for frequent calibration. This product is suitable for automatic dosing of circulating water, chlorination control of swimming pools, and accurate measurement of residual gas content in aqueous solutions in drinking water treatment plants, drinking water distribution networks, swimming pools, and hospital wastewater.
957 +== 6.1 Specification: ==
958 958  
959 959  
960 +* **Power Input**: DC7~~30
961 +
962 +* **Power Consumption** : 0.19W
963 +
964 +* **Interface**: RS485. 9600 Baud Rate
965 +
966 +* **CL Range & Resolution:**
967 +** **CL2ML** : 0.02 ~~ 20 μS/cm
968 +** **CL10ML**: 0.2 ~~ 200.0 μS/cm
969 +** **ECK1.0** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
970 +** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
971 +
972 +* **EC Accuracy**: ±1% FS
973 +* **Temperature Accuracy: **±0.5 °C
974 +* **Working environment:**
975 +** Ambient Temperature: 0–60°C
976 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
977 +* **IP Rated**: IP68
978 +
979 +* **Max Pressure**: 0.6MPa
980 +
960 960  = 7.  Water Quality Sensor Datasheet =