Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/25 09:38
From version 61.9
edited by Karry Zhuang
on 2025/07/15 15:58
on 2025/07/15 15:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. karry1 +XWiki.Xiaoling - Content
-
... ... @@ -19,20 +19,20 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 -** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 22 +** **ECK1.0** : 2 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm 25 25 26 26 * **EC Accuracy**: ±1% FS 26 + 27 +* **Temperature Measure Range**: -20 ~~ 60 °C 28 + 27 27 * **Temperature Accuracy: **±0.5 °C 28 -* **Working environment:** 29 -** Ambient Temperature: 0–60°C 30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 30 + 32 32 * **IP Rated**: IP68 33 33 34 34 * **Max Pressure**: 0.6MPa 35 35 35 + 36 36 == 1.2 Application for Different Range == 37 37 38 38 ... ... @@ -42,17 +42,15 @@ 42 42 == 1.3 Wiring == 43 43 44 44 45 -[[image:image-2024 1129142314-1.png||height="352" width="1108"]]45 +[[image:image-20240720172533-1.png||height="347" width="569"]] 46 46 47 47 48 48 == 1.4 Mechinical Drawing == 49 49 50 - ECK1 and ECK10 ECK200 51 51 51 +[[image:image-20240714174241-2.png]] 52 52 53 -[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] 54 54 55 - 56 56 == 1.5 Installation == 57 57 58 58 ... ... @@ -102,6 +102,7 @@ 102 102 103 103 * The equipment should be calibrated before each use. It is recommended to calibrate it every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). 104 104 103 + 105 105 == 1.7 RS485 Commands == 106 106 107 107 ... ... @@ -128,7 +128,6 @@ 128 128 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 129 129 130 130 131 - 132 132 === 1.7.2 Change address === 133 133 134 134 ... ... @@ -166,6 +166,7 @@ 166 166 0X8F 167 167 ))) 168 168 167 + 169 169 === 1.7.4 Query data === 170 170 171 171 ... ... @@ -207,11 +207,8 @@ 207 207 **For example**, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm,temperature: 35.6℃ Convert the returned data to decimal and divide by 10. 208 208 209 209 210 -ECK200 211 - 212 212 === 1.7.5 Calibration Method === 213 213 214 -ECK1 and ECK10.0 215 215 216 216 This device uses one-point calibration, and you need to prepare a known E standard solution. When mileage K=1, 1~~2000 uses 1413μS/cm standard solution, and when mileage K=10, 10~~20000 uses 12.88mS/cm standard solution. 217 217 ... ... @@ -256,29 +256,6 @@ 256 256 |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50 257 257 258 258 259 - 260 -ECK200.0 261 - 262 -For the device with address 01, use 1413uS/cm standard solution to calibrate the first point. Send frame: 1413. Convert hexadecimal to 585. Write 0001, 00 00, 0585 to 0x0120, 0x0121, 0x0122 respectively. 263 - 264 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) 265 -|=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Register Address|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Register length|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Data length|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)Register contents|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Data|=(% style="width: 53px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 53px;background-color:#4F81BD;color:white" %)CRC16 high 266 -|(% style="width:99px" %)0X01|(% style="width:112px" %)0X10|(% style="width:135px" %)0X01 0X02|(% style="width:126px" %)0X00 0X03|(% style="width:85px" %)0X06|(% style="width:1px" %)((( 267 -0X00 268 -0X01 269 -0X00 270 -0X00 271 -0X05 272 -0X85 273 -)))|(% style="width:1px" %)0X04|(% style="width:1px" %)((( 274 -0X00 275 -0X00 276 -0X37 277 -0X32 278 -)))|(% style="width:1px" %)0XBD|(% style="width:1px" %)0XFC 279 - 280 - 281 - 282 282 = 2. DR-PH01 Water PH Sensor = 283 283 284 284 == 2.1 Specification == ... ... @@ -300,9 +300,7 @@ 300 300 301 301 * **Temperature measurement error**: ±0.5°C 302 302 303 -* **Working environment:** 304 -** Ambient Temperature: 0–60°C 305 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 276 +* **Temperature Measure Range**: -20 ~~ 60 °C 306 306 307 307 * **Temperature Accuracy: **±0.5 °C 308 308 ... ... @@ -310,6 +310,7 @@ 310 310 311 311 * **Max Pressure**: 0.6MPa 312 312 284 + 313 313 == 2.2 Wiring == 314 314 315 315 ... ... @@ -371,6 +371,7 @@ 371 371 372 372 * The equipment should be calibrated before each use. For long-term use, it is recommended to calibrate once every 3 months. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). After aging, the electrodes should be replaced in time. 373 373 346 + 374 374 == 2.6 RS485 Commands == 375 375 376 376 ... ... @@ -509,14 +509,13 @@ 509 509 510 510 * **Stability**: ≤2mv/24 hours 511 511 512 -* **Working environment:** 513 -** Ambient Temperature: 0–60°C 514 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 485 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 515 515 516 516 * **IP Rated**: IP68 517 517 518 518 * **Max Pressure**: 0.6MPa 519 519 491 + 520 520 == 3.2 Wiring == 521 521 522 522 ... ... @@ -587,6 +587,7 @@ 587 587 |=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Original address|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 64.75px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 high 588 588 |(% style="width:99px" %)0XFE |(% style="width:112px" %)0X03|(% style="width:135px" %)0X00|(% style="width:126px" %)0X50|(% style="width:85px" %)0X00|(% style="width:1px" %)0X00|(% style="width:1px" %)0X51|(% style="width:1px" %)0XD4 589 589 562 + 590 590 **response:** 591 591 592 592 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) ... ... @@ -593,6 +593,7 @@ 593 593 |=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 594 594 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 595 595 569 + 596 596 === 3.6.2 Change address === 597 597 598 598 ... ... @@ -630,6 +630,7 @@ 630 630 0X96 631 631 ))) 632 632 607 + 633 633 === 3.6.4 Query data === 634 634 635 635 ... ... @@ -682,11 +682,11 @@ 682 682 == 4.1 Specification == 683 683 684 684 685 -* **Measuring range**: 0-20mg/L, 0 –50℃660 +* **Measuring range**: 0-20mg/L, 0-50°C 686 686 687 -* **Accuracy**: 3%, ±0.5 ℃662 +* **Accuracy**: 3%, ±0.5°C 688 688 689 -* **Resolution**: 0.01 mg/L, 0.01 ℃664 +* **Resolution**: 0.01 mg/L, 0.01°C 690 690 691 691 * **Maximum operating pressure**: 6 bar 692 692 ... ... @@ -694,9 +694,7 @@ 694 694 695 695 * **Power supply voltage**: 5-24V DC 696 696 697 -* **Working environment:** 698 -** Ambient Temperature: 0–60°C 699 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 672 +* **Working environment**: temperature 0-60°C; humidity <95%RH 700 700 701 701 * **Power consumption**: ≤0.5W 702 702 ... ... @@ -709,10 +709,13 @@ 709 709 == 4.3 Impedance requirements for current signals == 710 710 711 711 712 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:40 0px" %)713 -|(% style="width:1 32px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**714 -|(% style="width:13 2px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**685 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 686 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 687 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 715 715 689 +[[image:image-20240718195414-8.png||height="100" width="575"]] 690 + 691 + 716 716 == 4.4 Mechinical Drawing == 717 717 718 718 ... ... @@ -726,6 +726,7 @@ 726 726 727 727 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 728 728 705 + 729 729 == 4.6 RS485 Commands == 730 730 731 731 ... ... @@ -769,6 +769,7 @@ 769 769 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 770 770 |(% style="width:99px" %)0X01|(% style="width:72px" %)0X10|(% style="width:64px" %)0X00|(% style="width:68px" %)0X0A|(% style="width:70px" %)0X00|(% style="width:72px" %)0X02|(% style="width:56px" %)0X61|(% style="width:56px" %)0XCA 771 771 749 + 772 772 === 4.6.3 Query data === 773 773 774 774 ... ... @@ -811,7 +811,7 @@ 811 811 == 5.1 Specification == 812 812 813 813 814 -* **Measuring range**: 0.1 ~~1000.0NTU792 +* **Measuring range**: 0.11000.0NTU 815 815 816 816 * **Accuracy**: ±5% 817 817 ... ... @@ -819,13 +819,11 @@ 819 819 820 820 * **Stability**: ≤3mV/24 hours 821 821 822 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 800 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 823 823 824 -* **Power supply voltage**: 5 ~~24V DC (when output signal is RS485),12~~24V DC (when output signal is 4~~20mA)802 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 825 825 826 -* **Working environment:** 827 -** Ambient Temperature: 0–60°C 828 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 804 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 829 829 830 830 * **Power consumption**: ≤ 0.5W 831 831 ... ... @@ -838,10 +838,11 @@ 838 838 == 5.3 Impedance requirements for current signals == 839 839 840 840 841 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:40 0px" %)842 -|(% style="width:1 32px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**843 -|(% style="width:13 2px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**817 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 818 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 819 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 844 844 821 + 845 845 == 5.4 Mechinical Drawing == 846 846 847 847 ... ... @@ -914,9 +914,3 @@ 914 914 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 915 915 916 916 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 917 - 918 - 919 -= 6. Water Quality Sensor Datasheet = 920 - 921 - 922 -* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.4 KB - Content
- image-20241129142314-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.2 MB - Content