Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/25 09:38
From version 61.8
edited by Karry Zhuang
on 2025/07/15 15:58
on 2025/07/15 15:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. karry1 +XWiki.Xiaoling - Content
-
... ... @@ -19,20 +19,20 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 -** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 22 +** **ECK1.0** : 2 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm 25 25 26 26 * **EC Accuracy**: ±1% FS 26 + 27 +* **Temperature Measure Range**: -20 ~~ 60 °C 28 + 27 27 * **Temperature Accuracy: **±0.5 °C 28 -* **Working environment:** 29 -** Ambient Temperature: 0–60°C 30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 30 + 32 32 * **IP Rated**: IP68 33 33 34 34 * **Max Pressure**: 0.6MPa 35 35 35 + 36 36 == 1.2 Application for Different Range == 37 37 38 38 ... ... @@ -42,17 +42,15 @@ 42 42 == 1.3 Wiring == 43 43 44 44 45 -[[image:image-2024 1129142314-1.png||height="352" width="1108"]]45 +[[image:image-20240720172533-1.png||height="347" width="569"]] 46 46 47 47 48 48 == 1.4 Mechinical Drawing == 49 49 50 - ECK1 and ECK10 ECK200 51 51 51 +[[image:image-20240714174241-2.png]] 52 52 53 -[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] 54 54 55 - 56 56 == 1.5 Installation == 57 57 58 58 ... ... @@ -102,6 +102,7 @@ 102 102 103 103 * The equipment should be calibrated before each use. It is recommended to calibrate it every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). 104 104 103 + 105 105 == 1.7 RS485 Commands == 106 106 107 107 ... ... @@ -128,7 +128,6 @@ 128 128 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 129 129 130 130 131 - 132 132 === 1.7.2 Change address === 133 133 134 134 ... ... @@ -166,6 +166,7 @@ 166 166 0X8F 167 167 ))) 168 168 167 + 169 169 === 1.7.4 Query data === 170 170 171 171 ... ... @@ -207,11 +207,8 @@ 207 207 **For example**, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm,temperature: 35.6℃ Convert the returned data to decimal and divide by 10. 208 208 209 209 210 -ECK200 211 - 212 212 === 1.7.5 Calibration Method === 213 213 214 -ECK1 and ECK10.0 215 215 216 216 This device uses one-point calibration, and you need to prepare a known E standard solution. When mileage K=1, 1~~2000 uses 1413μS/cm standard solution, and when mileage K=10, 10~~20000 uses 12.88mS/cm standard solution. 217 217 ... ... @@ -256,30 +256,6 @@ 256 256 |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50 257 257 258 258 259 - 260 -ECK200.0 261 - 262 -For the device with address 01, use 1413uS/cm standard solution to calibrate the first point. Send frame: 1413. Convert hexadecimal to 585. Write 0001, 00 00, 0585 to 0x0120, 0x0121, 0x0122 respectively. 263 - 264 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) 265 -|=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Register Address|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Register length|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Data length|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)Register contents|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Data|=(% style="width: 53px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 53px;background-color:#4F81BD;color:white" %)CRC16 high 266 -|(% style="width:99px" %)0X01|(% style="width:112px" %)0X10|(% style="width:135px" %)0X01 0X02|(% style="width:126px" %)0X00 0X03|(% style="width:85px" %)0X06|(% style="width:1px" %)((( 267 -0X00 268 -0X01 269 -0X00 270 -0X000X00 271 -0X01 272 -0X00 273 -0X00 274 -)))|(% style="width:1px" %)0X04|(% style="width:1px" %)((( 275 -0X00 276 -0X00 277 -0X37 278 -0X32 279 -)))|(% style="width:1px" %)0XBD|(% style="width:1px" %)0XFC 280 - 281 - 282 - 283 283 = 2. DR-PH01 Water PH Sensor = 284 284 285 285 == 2.1 Specification == ... ... @@ -301,9 +301,7 @@ 301 301 302 302 * **Temperature measurement error**: ±0.5°C 303 303 304 -* **Working environment:** 305 -** Ambient Temperature: 0–60°C 306 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 276 +* **Temperature Measure Range**: -20 ~~ 60 °C 307 307 308 308 * **Temperature Accuracy: **±0.5 °C 309 309 ... ... @@ -311,6 +311,7 @@ 311 311 312 312 * **Max Pressure**: 0.6MPa 313 313 284 + 314 314 == 2.2 Wiring == 315 315 316 316 ... ... @@ -372,6 +372,7 @@ 372 372 373 373 * The equipment should be calibrated before each use. For long-term use, it is recommended to calibrate once every 3 months. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). After aging, the electrodes should be replaced in time. 374 374 346 + 375 375 == 2.6 RS485 Commands == 376 376 377 377 ... ... @@ -510,14 +510,13 @@ 510 510 511 511 * **Stability**: ≤2mv/24 hours 512 512 513 -* **Working environment:** 514 -** Ambient Temperature: 0–60°C 515 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 485 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 516 516 517 517 * **IP Rated**: IP68 518 518 519 519 * **Max Pressure**: 0.6MPa 520 520 491 + 521 521 == 3.2 Wiring == 522 522 523 523 ... ... @@ -588,6 +588,7 @@ 588 588 |=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Original address|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 64.75px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 high 589 589 |(% style="width:99px" %)0XFE |(% style="width:112px" %)0X03|(% style="width:135px" %)0X00|(% style="width:126px" %)0X50|(% style="width:85px" %)0X00|(% style="width:1px" %)0X00|(% style="width:1px" %)0X51|(% style="width:1px" %)0XD4 590 590 562 + 591 591 **response:** 592 592 593 593 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) ... ... @@ -594,6 +594,7 @@ 594 594 |=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 595 595 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 596 596 569 + 597 597 === 3.6.2 Change address === 598 598 599 599 ... ... @@ -631,6 +631,7 @@ 631 631 0X96 632 632 ))) 633 633 607 + 634 634 === 3.6.4 Query data === 635 635 636 636 ... ... @@ -683,11 +683,11 @@ 683 683 == 4.1 Specification == 684 684 685 685 686 -* **Measuring range**: 0-20mg/L, 0 –50℃660 +* **Measuring range**: 0-20mg/L, 0-50°C 687 687 688 -* **Accuracy**: 3%, ±0.5 ℃662 +* **Accuracy**: 3%, ±0.5°C 689 689 690 -* **Resolution**: 0.01 mg/L, 0.01 ℃664 +* **Resolution**: 0.01 mg/L, 0.01°C 691 691 692 692 * **Maximum operating pressure**: 6 bar 693 693 ... ... @@ -695,9 +695,7 @@ 695 695 696 696 * **Power supply voltage**: 5-24V DC 697 697 698 -* **Working environment:** 699 -** Ambient Temperature: 0–60°C 700 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 672 +* **Working environment**: temperature 0-60°C; humidity <95%RH 701 701 702 702 * **Power consumption**: ≤0.5W 703 703 ... ... @@ -710,10 +710,13 @@ 710 710 == 4.3 Impedance requirements for current signals == 711 711 712 712 713 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:40 0px" %)714 -|(% style="width:1 32px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**715 -|(% style="width:13 2px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**685 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 686 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 687 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 716 716 689 +[[image:image-20240718195414-8.png||height="100" width="575"]] 690 + 691 + 717 717 == 4.4 Mechinical Drawing == 718 718 719 719 ... ... @@ -727,6 +727,7 @@ 727 727 728 728 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 729 729 705 + 730 730 == 4.6 RS485 Commands == 731 731 732 732 ... ... @@ -770,6 +770,7 @@ 770 770 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 771 771 |(% style="width:99px" %)0X01|(% style="width:72px" %)0X10|(% style="width:64px" %)0X00|(% style="width:68px" %)0X0A|(% style="width:70px" %)0X00|(% style="width:72px" %)0X02|(% style="width:56px" %)0X61|(% style="width:56px" %)0XCA 772 772 749 + 773 773 === 4.6.3 Query data === 774 774 775 775 ... ... @@ -812,7 +812,7 @@ 812 812 == 5.1 Specification == 813 813 814 814 815 -* **Measuring range**: 0.1 ~~1000.0NTU792 +* **Measuring range**: 0.11000.0NTU 816 816 817 817 * **Accuracy**: ±5% 818 818 ... ... @@ -820,13 +820,11 @@ 820 820 821 821 * **Stability**: ≤3mV/24 hours 822 822 823 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 800 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 824 824 825 -* **Power supply voltage**: 5 ~~24V DC (when output signal is RS485),12~~24V DC (when output signal is 4~~20mA)802 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 826 826 827 -* **Working environment:** 828 -** Ambient Temperature: 0–60°C 829 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 804 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 830 830 831 831 * **Power consumption**: ≤ 0.5W 832 832 ... ... @@ -839,10 +839,11 @@ 839 839 == 5.3 Impedance requirements for current signals == 840 840 841 841 842 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:40 0px" %)843 -|(% style="width:1 32px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**844 -|(% style="width:13 2px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**817 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 818 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 819 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 845 845 821 + 846 846 == 5.4 Mechinical Drawing == 847 847 848 848 ... ... @@ -915,9 +915,3 @@ 915 915 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 916 916 917 917 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 918 - 919 - 920 -= 6. Water Quality Sensor Datasheet = 921 - 922 - 923 -* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.4 KB - Content
- image-20241129142314-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.2 MB - Content