... ... @@ -21,14 +21,13 @@
21 21  ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm
22 22  ** **ECK1.0** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 23  ** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm  Resolution: 1 μS/cm
25 25  
26 26  * **EC Accuracy**: ±1% FS
26 +
27 +* **Temperature Measure Range**: -20 ~~ 60 °C
28 +
27 27  * **Temperature Accuracy: **±0.5 °C
28 -* **Working environment:**
29 -** Ambient Temperature: 0–60°C
30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
31 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments
30 +
32 32  * **IP Rated**: IP68
33 33  
34 34  * **Max Pressure**: 0.6MPa
... ... @@ -42,17 +42,15 @@
42 42  == 1.3 Wiring ==
43 43  
44 44  
45 -[[image:image-20241129142314-1.png||height="352" width="1108"]]
44 +[[image:image-20240720172533-1.png||height="347" width="569"]]
46 46  
47 47  
48 48  == 1.4 Mechinical Drawing ==
49 49  
50 - ECK1 and ECK10  ECK200
51 51  
50 +[[image:image-20240714174241-2.png]]
52 52  
53 -[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]]
54 54  
55 -
56 56  == 1.5 Installation ==
57 57  
58 58  
... ... @@ -111,7 +111,6 @@
111 111  
112 112  === 1.7.1 Query address ===
113 113  
114 -ECK1 and ECK10.0
115 115  
116 116  **send:**
117 117  
... ... @@ -128,10 +128,6 @@
128 128  |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high
129 129  |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0
130 130  
131 -
132 -
133 -ECK200.0
134 -
135 135  === 1.7.2 Change address ===
136 136  
137 137  
... ... @@ -276,9 +276,7 @@
276 276  
277 277  * **Temperature measurement error**: ±0.5°C
278 278  
279 -* **Working environment:**
280 -** Ambient Temperature: 0–60°C
281 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
271 +* **Temperature Measure Range**: -20 ~~ 60 °C
282 282  
283 283  * **Temperature Accuracy: **±0.5 °C
284 284  
... ... @@ -485,9 +485,7 @@
485 485  
486 486  * **Stability**: ≤2mv/24 hours
487 487  
488 -* **Working environment:**
489 -** Ambient Temperature: 0–60°C
490 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
478 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH
491 491  
492 492  * **IP Rated**: IP68
493 493  
... ... @@ -658,11 +658,11 @@
658 658  == 4.1 Specification ==
659 659  
660 660  
661 -* **Measuring range**: 0-20mg/L, 050
649 +* **Measuring range**: 0-20mg/L, 0-50°C
662 662  
663 -* **Accuracy**: 3%, ±0.5
651 +* **Accuracy**: 3%, ±0.5°C
664 664  
665 -* **Resolution**: 0.01 mg/L, 0.01
653 +* **Resolution**: 0.01 mg/L, 0.01°C
666 666  
667 667  * **Maximum operating pressure**: 6 bar
668 668  
... ... @@ -670,9 +670,7 @@
670 670  
671 671  * **Power supply voltage**: 5-24V DC
672 672  
673 -* **Working environment:**
674 -** Ambient Temperature: 0–60°C
675 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
661 +* **Working environment**: temperature 0-60°C; humidity <95%RH
676 676  
677 677  * **Power consumption**: ≤0.5W
678 678  
... ... @@ -795,13 +795,11 @@
795 795  
796 796  * **Stability**: ≤3mV/24 hours
797 797  
798 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01)
784 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01)
799 799  
800 -* **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA)
786 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA)
801 801  
802 -* **Working environment:**
803 -** Ambient Temperature: 0–60°C
804 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
788 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH
805 805  
806 806  * **Power consumption**: ≤ 0.5W
807 807  
... ... @@ -896,3 +896,5 @@
896 896  
897 897  
898 898  * **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
883 +
884 +
1752564223905-283.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -144.4 KB
Content
image-20241129142314-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -1.2 MB
Content