Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 60.8
edited by Karry Zhuang
on 2025/07/15 15:39
on 2025/07/15 15:39
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. karry1 +XWiki.Xiaoling - Content
-
... ... @@ -21,14 +21,13 @@ 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 22 ** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 25 25 26 26 * **EC Accuracy**: ±1% FS 26 + 27 +* **Temperature Measure Range**: -20 ~~ 60 °C 28 + 27 27 * **Temperature Accuracy: **±0.5 °C 28 -* **Working environment:** 29 -** Ambient Temperature: 0–60°C 30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 30 + 32 32 * **IP Rated**: IP68 33 33 34 34 * **Max Pressure**: 0.6MPa ... ... @@ -42,17 +42,15 @@ 42 42 == 1.3 Wiring == 43 43 44 44 45 -[[image:image-2024 1129142314-1.png||height="352" width="1108"]]44 +[[image:image-20240720172533-1.png||height="347" width="569"]] 46 46 47 47 48 48 == 1.4 Mechinical Drawing == 49 49 50 - ECK1 and ECK10 ECK200 51 51 50 +[[image:image-20240714174241-2.png]] 52 52 53 -[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] 54 54 55 - 56 56 == 1.5 Installation == 57 57 58 58 ... ... @@ -111,7 +111,6 @@ 111 111 112 112 === 1.7.1 Query address === 113 113 114 -ECK1 and ECK10.0 115 115 116 116 **send:** 117 117 ... ... @@ -128,10 +128,6 @@ 128 128 |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 129 129 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 130 130 131 - 132 - 133 -ECK200.0 134 - 135 135 === 1.7.2 Change address === 136 136 137 137 ... ... @@ -276,9 +276,7 @@ 276 276 277 277 * **Temperature measurement error**: ±0.5°C 278 278 279 -* **Working environment:** 280 -** Ambient Temperature: 0–60°C 281 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 271 +* **Temperature Measure Range**: -20 ~~ 60 °C 282 282 283 283 * **Temperature Accuracy: **±0.5 °C 284 284 ... ... @@ -485,9 +485,7 @@ 485 485 486 486 * **Stability**: ≤2mv/24 hours 487 487 488 -* **Working environment:** 489 -** Ambient Temperature: 0–60°C 490 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 478 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 491 491 492 492 * **IP Rated**: IP68 493 493 ... ... @@ -658,11 +658,11 @@ 658 658 == 4.1 Specification == 659 659 660 660 661 -* **Measuring range**: 0-20mg/L, 0 –50℃649 +* **Measuring range**: 0-20mg/L, 0-50°C 662 662 663 -* **Accuracy**: 3%, ±0.5 ℃651 +* **Accuracy**: 3%, ±0.5°C 664 664 665 -* **Resolution**: 0.01 mg/L, 0.01 ℃653 +* **Resolution**: 0.01 mg/L, 0.01°C 666 666 667 667 * **Maximum operating pressure**: 6 bar 668 668 ... ... @@ -670,9 +670,7 @@ 670 670 671 671 * **Power supply voltage**: 5-24V DC 672 672 673 -* **Working environment:** 674 -** Ambient Temperature: 0–60°C 675 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 661 +* **Working environment**: temperature 0-60°C; humidity <95%RH 676 676 677 677 * **Power consumption**: ≤0.5W 678 678 ... ... @@ -795,13 +795,11 @@ 795 795 796 796 * **Stability**: ≤3mV/24 hours 797 797 798 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 784 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 799 799 800 -* **Power supply voltage**: 5 ~~24V DC (when output signal is RS485),12~~24V DC (when output signal is 4~~20mA)786 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 801 801 802 -* **Working environment:** 803 -** Ambient Temperature: 0–60°C 804 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 788 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 805 805 806 806 * **Power consumption**: ≤ 0.5W 807 807 ... ... @@ -896,3 +896,5 @@ 896 896 897 897 898 898 * **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]** 883 + 884 +
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.4 KB - Content
- image-20241129142314-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.2 MB - Content