Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 60.4
edited by Karry Zhuang
on 2025/07/15 15:33
on 2025/07/15 15:33
Change comment:
There is no comment for this version
To version 56.1
edited by Karry Zhuang
on 2024/12/24 09:55
on 2024/12/24 09:55
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,14 +21,9 @@ 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 22 ** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 25 25 26 26 * **EC Accuracy**: ±1% FS 27 27 * **Temperature Accuracy: **±0.5 °C 28 -* **Working environment:** 29 -** Ambient Temperature: 0–60°C 30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 32 32 * **IP Rated**: IP68 33 33 34 34 * **Max Pressure**: 0.6MPa ... ... @@ -48,10 +48,9 @@ 48 48 == 1.4 Mechinical Drawing == 49 49 50 50 46 +[[image:image-20240714174241-2.png]] 51 51 52 -[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] 53 53 54 - 55 55 == 1.5 Installation == 56 56 57 57 ... ... @@ -270,9 +270,7 @@ 270 270 271 271 * **Temperature measurement error**: ±0.5°C 272 272 273 -* **Working environment:** 274 -** Ambient Temperature: 0–60°C 275 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 267 +* **Temperature Measure Range**: -20 ~~ 60 °C 276 276 277 277 * **Temperature Accuracy: **±0.5 °C 278 278 ... ... @@ -479,9 +479,7 @@ 479 479 480 480 * **Stability**: ≤2mv/24 hours 481 481 482 -* **Working environment:** 483 -** Ambient Temperature: 0–60°C 484 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 474 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 485 485 486 486 * **IP Rated**: IP68 487 487 ... ... @@ -652,11 +652,11 @@ 652 652 == 4.1 Specification == 653 653 654 654 655 -* **Measuring range**: 0-20mg/L, 0 –50℃645 +* **Measuring range**: 0-20mg/L, 0-50°C 656 656 657 -* **Accuracy**: 3%, ±0.5 ℃647 +* **Accuracy**: 3%, ±0.5°C 658 658 659 -* **Resolution**: 0.01 mg/L, 0.01 ℃649 +* **Resolution**: 0.01 mg/L, 0.01°C 660 660 661 661 * **Maximum operating pressure**: 6 bar 662 662 ... ... @@ -664,9 +664,7 @@ 664 664 665 665 * **Power supply voltage**: 5-24V DC 666 666 667 -* **Working environment:** 668 -** Ambient Temperature: 0–60°C 669 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 657 +* **Working environment**: temperature 0-60°C; humidity <95%RH 670 670 671 671 * **Power consumption**: ≤0.5W 672 672 ... ... @@ -793,9 +793,7 @@ 793 793 794 794 * **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 795 795 796 -* **Working environment:** 797 -** Ambient Temperature: 0–60°C 798 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 784 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 799 799 800 800 * **Power consumption**: ≤ 0.5W 801 801
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.4 KB - Content