Changes for page Water Quality Sensors

Last modified by Karry Zhuang on 2025/07/18 16:37

From version 60.4
edited by Karry Zhuang
on 2025/07/15 15:33
Change comment: There is no comment for this version
To version 55.1
edited by Xiaoling
on 2024/12/21 11:04
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.karry
1 +XWiki.Xiaoling
Content
... ... @@ -21,14 +21,13 @@
21 21  ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm
22 22  ** **ECK1.0** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 23  ** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm  Resolution: 1 μS/cm
25 25  
26 26  * **EC Accuracy**: ±1% FS
26 +
27 +* **Temperature Measure Range**: -20 ~~ 60 °C
28 +
27 27  * **Temperature Accuracy: **±0.5 °C
28 -* **Working environment:**
29 -** Ambient Temperature: 0–60°C
30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
31 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments
30 +
32 32  * **IP Rated**: IP68
33 33  
34 34  * **Max Pressure**: 0.6MPa
... ... @@ -48,10 +48,9 @@
48 48  == 1.4 Mechinical Drawing ==
49 49  
50 50  
50 +[[image:image-20240714174241-2.png]]
51 51  
52 -[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]]
53 53  
54 -
55 55  == 1.5 Installation ==
56 56  
57 57  
... ... @@ -270,9 +270,7 @@
270 270  
271 271  * **Temperature measurement error**: ±0.5°C
272 272  
273 -* **Working environment:**
274 -** Ambient Temperature: 0–60°C
275 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
271 +* **Temperature Measure Range**: -20 ~~ 60 °C
276 276  
277 277  * **Temperature Accuracy: **±0.5 °C
278 278  
... ... @@ -479,9 +479,7 @@
479 479  
480 480  * **Stability**: ≤2mv/24 hours
481 481  
482 -* **Working environment:**
483 -** Ambient Temperature: 0–60°C
484 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
478 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH
485 485  
486 486  * **IP Rated**: IP68
487 487  
... ... @@ -652,11 +652,11 @@
652 652  == 4.1 Specification ==
653 653  
654 654  
655 -* **Measuring range**: 0-20mg/L, 050
649 +* **Measuring range**: 0-20mg/L, 0-50°C
656 656  
657 -* **Accuracy**: 3%, ±0.5
651 +* **Accuracy**: 3%, ±0.5°C
658 658  
659 -* **Resolution**: 0.01 mg/L, 0.01
653 +* **Resolution**: 0.01 mg/L, 0.01°C
660 660  
661 661  * **Maximum operating pressure**: 6 bar
662 662  
... ... @@ -664,9 +664,7 @@
664 664  
665 665  * **Power supply voltage**: 5-24V DC
666 666  
667 -* **Working environment:**
668 -** Ambient Temperature: 0–60°C
669 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
661 +* **Working environment**: temperature 0-60°C; humidity <95%RH
670 670  
671 671  * **Power consumption**: ≤0.5W
672 672  
... ... @@ -793,9 +793,7 @@
793 793  
794 794  * **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA)
795 795  
796 -* **Working environment:**
797 -** Ambient Temperature: 0–60°C
798 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
788 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH
799 799  
800 800  * **Power consumption**: ≤ 0.5W
801 801  
1752564223905-283.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -144.4 KB
Content