Changes for page Water Quality Sensors

Last modified by Karry Zhuang on 2025/07/18 16:37

From version 60.4
edited by Karry Zhuang
on 2025/07/15 15:33
Change comment: There is no comment for this version
To version 45.95
edited by Xiaoling
on 2024/08/06 18:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.karry
1 +XWiki.Xiaoling
Content
... ... @@ -19,16 +19,15 @@
19 19  * **EC Range & Resolution:**
20 20  ** **ECK0.01** : 0.02 ~~ 20 μS/cm
21 21  ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm
22 -** **ECK1.0** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 -** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm  Resolution: 1 μS/cm
22 +** **ECK1.0** : 2 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 +** **ECK10.0** : 20 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
25 25  
26 26  * **EC Accuracy**: ±1% FS
26 +
27 +* **Temperature Measure Range**: -20 ~~ 60 °C
28 +
27 27  * **Temperature Accuracy: **±0.5 °C
28 -* **Working environment:**
29 -** Ambient Temperature: 0–60°C
30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
31 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments
30 +
32 32  * **IP Rated**: IP68
33 33  
34 34  * **Max Pressure**: 0.6MPa
... ... @@ -42,16 +42,15 @@
42 42  == 1.3 Wiring ==
43 43  
44 44  
45 -[[image:image-20241129142314-1.png||height="352" width="1108"]]
44 +[[image:image-20240720172533-1.png||height="347" width="569"]]
46 46  
47 47  
48 48  == 1.4 Mechinical Drawing ==
49 49  
50 50  
50 +[[image:image-20240714174241-2.png]]
51 51  
52 -[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]]
53 53  
54 -
55 55  == 1.5 Installation ==
56 56  
57 57  
... ... @@ -270,9 +270,7 @@
270 270  
271 271  * **Temperature measurement error**: ±0.5°C
272 272  
273 -* **Working environment:**
274 -** Ambient Temperature: 0–60°C
275 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
271 +* **Temperature Measure Range**: -20 ~~ 60 °C
276 276  
277 277  * **Temperature Accuracy: **±0.5 °C
278 278  
... ... @@ -479,9 +479,7 @@
479 479  
480 480  * **Stability**: ≤2mv/24 hours
481 481  
482 -* **Working environment:**
483 -** Ambient Temperature: 0–60°C
484 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
478 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH
485 485  
486 486  * **IP Rated**: IP68
487 487  
... ... @@ -647,16 +647,17 @@
647 647  0XC3
648 648  )))
649 649  
644 +
650 650  = 4. DR-DO1 Dissolved Oxygen Sensor =
651 651  
652 652  == 4.1 Specification ==
653 653  
654 654  
655 -* **Measuring range**: 0-20mg/L, 050
650 +* **Measuring range**: 0-20mg/L, 0-50°C
656 656  
657 -* **Accuracy**: 3%, ±0.5
652 +* **Accuracy**: 3%, ±0.5°C
658 658  
659 -* **Resolution**: 0.01 mg/L, 0.01
654 +* **Resolution**: 0.01 mg/L, 0.01°C
660 660  
661 661  * **Maximum operating pressure**: 6 bar
662 662  
... ... @@ -664,9 +664,7 @@
664 664  
665 665  * **Power supply voltage**: 5-24V DC
666 666  
667 -* **Working environment:**
668 -** Ambient Temperature: 0–60°C
669 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
662 +* **Working environment**: temperature 0-60°C; humidity <95%RH
670 670  
671 671  * **Power consumption**: ≤0.5W
672 672  
... ... @@ -679,10 +679,9 @@
679 679  == 4.3 Impedance requirements for current signals ==
680 680  
681 681  
682 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %)
683 -|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
684 -|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
675 +[[image:image-20240718195414-8.png||height="100" width="575"]]
685 685  
677 +
686 686  == 4.4 Mechinical Drawing ==
687 687  
688 688  
... ... @@ -781,7 +781,7 @@
781 781  == 5.1 Specification ==
782 782  
783 783  
784 -* **Measuring range**: 0.1~~1000.0NTU
776 +* **Measuring range**: 0.11000.0NTU
785 785  
786 786  * **Accuracy**: ±5%
787 787  
... ... @@ -789,13 +789,11 @@
789 789  
790 790  * **Stability**: ≤3mV/24 hours
791 791  
792 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01)
784 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01)
793 793  
794 -* **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA)
786 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA)
795 795  
796 -* **Working environment:**
797 -** Ambient Temperature: 0–60°C
798 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
788 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH
799 799  
800 800  * **Power consumption**: ≤ 0.5W
801 801  
... ... @@ -808,10 +808,11 @@
808 808  == 5.3 Impedance requirements for current signals ==
809 809  
810 810  
811 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %)
812 -|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
813 -|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
801 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %)
802 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V**
803 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω**
814 814  
805 +
815 815  == 5.4 Mechinical Drawing ==
816 816  
817 817  
... ... @@ -884,9 +884,3 @@
884 884  For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C
885 885  
886 886  02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU
887 -
888 -
889 -= 6.  Water Quality Sensor Datasheet =
890 -
891 -
892 -* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
1752564223905-283.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -144.4 KB
Content
image-20241129142314-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -1.2 MB
Content