... ... @@ -21,14 +21,13 @@
21 21  ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm
22 22  ** **ECK1.0** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 23  ** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm  Resolution: 1 μS/cm
25 25  
26 26  * **EC Accuracy**: ±1% FS
26 +
27 +* **Temperature Measure Range**: -20 ~~ 60 °C
28 +
27 27  * **Temperature Accuracy: **±0.5 °C
28 -* **Working environment:**
29 -** Ambient Temperature: 0–60°C
30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
31 -** ECK200.0
30 +
32 32  * **IP Rated**: IP68
33 33  
34 34  * **Max Pressure**: 0.6MPa
... ... @@ -42,7 +42,7 @@
42 42  == 1.3 Wiring ==
43 43  
44 44  
45 -[[image:image-20241129142314-1.png||height="352" width="1108"]]
44 +[[image:image-20240720172533-1.png||height="347" width="569"]]
46 46  
47 47  
48 48  == 1.4 Mechinical Drawing ==
... ... @@ -269,9 +269,7 @@
269 269  
270 270  * **Temperature measurement error**: ±0.5°C
271 271  
272 -* **Working environment:**
273 -** Ambient Temperature: 0–60°C
274 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
271 +* **Temperature Measure Range**: -20 ~~ 60 °C
275 275  
276 276  * **Temperature Accuracy: **±0.5 °C
277 277  
... ... @@ -478,9 +478,7 @@
478 478  
479 479  * **Stability**: ≤2mv/24 hours
480 480  
481 -* **Working environment:**
482 -** Ambient Temperature: 0–60°C
483 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
478 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH
484 484  
485 485  * **IP Rated**: IP68
486 486  
... ... @@ -651,11 +651,11 @@
651 651  == 4.1 Specification ==
652 652  
653 653  
654 -* **Measuring range**: 0-20mg/L, 050
649 +* **Measuring range**: 0-20mg/L, 0-50°C
655 655  
656 -* **Accuracy**: 3%, ±0.5
651 +* **Accuracy**: 3%, ±0.5°C
657 657  
658 -* **Resolution**: 0.01 mg/L, 0.01
653 +* **Resolution**: 0.01 mg/L, 0.01°C
659 659  
660 660  * **Maximum operating pressure**: 6 bar
661 661  
... ... @@ -663,9 +663,7 @@
663 663  
664 664  * **Power supply voltage**: 5-24V DC
665 665  
666 -* **Working environment:**
667 -** Ambient Temperature: 0–60°C
668 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
661 +* **Working environment**: temperature 0-60°C; humidity <95%RH
669 669  
670 670  * **Power consumption**: ≤0.5W
671 671  
... ... @@ -788,13 +788,11 @@
788 788  
789 789  * **Stability**: ≤3mV/24 hours
790 790  
791 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01)
784 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01)
792 792  
793 -* **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA)
786 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA)
794 794  
795 -* **Working environment:**
796 -** Ambient Temperature: 0–60°C
797 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
788 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH
798 798  
799 799  * **Power consumption**: ≤ 0.5W
800 800  
... ... @@ -889,3 +889,5 @@
889 889  
890 890  
891 891  * **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
883 +
884 +
1752564223905-283.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -144.4 KB
Content
image-20241129142314-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -1.2 MB
Content