Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 60.1
edited by Karry Zhuang
on 2025/07/15 15:23
on 2025/07/15 15:23
Change comment:
Uploaded new attachment "1752564223905-283.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. karry1 +XWiki.Xiaoling - Content
-
... ... @@ -19,20 +19,20 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 -** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 22 +** **ECK1.0** : 2 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm 25 25 26 26 * **EC Accuracy**: ±1% FS 26 + 27 +* **Temperature Measure Range**: -20 ~~ 60 °C 28 + 27 27 * **Temperature Accuracy: **±0.5 °C 28 -* **Working environment:** 29 -** Ambient Temperature: 0–60°C 30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 -** ECK200.0 30 + 32 32 * **IP Rated**: IP68 33 33 34 34 * **Max Pressure**: 0.6MPa 35 35 35 + 36 36 == 1.2 Application for Different Range == 37 37 38 38 ... ... @@ -42,7 +42,7 @@ 42 42 == 1.3 Wiring == 43 43 44 44 45 -[[image:image-2024 1129142314-1.png||height="352" width="1108"]]45 +[[image:image-20240720172533-1.png||height="347" width="569"]] 46 46 47 47 48 48 == 1.4 Mechinical Drawing == ... ... @@ -100,6 +100,7 @@ 100 100 101 101 * The equipment should be calibrated before each use. It is recommended to calibrate it every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). 102 102 103 + 103 103 == 1.7 RS485 Commands == 104 104 105 105 ... ... @@ -125,6 +125,7 @@ 125 125 |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 126 126 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 127 127 129 + 128 128 === 1.7.2 Change address === 129 129 130 130 ... ... @@ -162,6 +162,7 @@ 162 162 0X8F 163 163 ))) 164 164 167 + 165 165 === 1.7.4 Query data === 166 166 167 167 ... ... @@ -248,6 +248,7 @@ 248 248 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 high 249 249 |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50 250 250 254 + 251 251 = 2. DR-PH01 Water PH Sensor = 252 252 253 253 == 2.1 Specification == ... ... @@ -269,9 +269,7 @@ 269 269 270 270 * **Temperature measurement error**: ±0.5°C 271 271 272 -* **Working environment:** 273 -** Ambient Temperature: 0–60°C 274 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 276 +* **Temperature Measure Range**: -20 ~~ 60 °C 275 275 276 276 * **Temperature Accuracy: **±0.5 °C 277 277 ... ... @@ -279,6 +279,7 @@ 279 279 280 280 * **Max Pressure**: 0.6MPa 281 281 284 + 282 282 == 2.2 Wiring == 283 283 284 284 ... ... @@ -340,6 +340,7 @@ 340 340 341 341 * The equipment should be calibrated before each use. For long-term use, it is recommended to calibrate once every 3 months. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). After aging, the electrodes should be replaced in time. 342 342 346 + 343 343 == 2.6 RS485 Commands == 344 344 345 345 ... ... @@ -478,14 +478,13 @@ 478 478 479 479 * **Stability**: ≤2mv/24 hours 480 480 481 -* **Working environment:** 482 -** Ambient Temperature: 0–60°C 483 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 485 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 484 484 485 485 * **IP Rated**: IP68 486 486 487 487 * **Max Pressure**: 0.6MPa 488 488 491 + 489 489 == 3.2 Wiring == 490 490 491 491 ... ... @@ -556,6 +556,7 @@ 556 556 |=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Original address|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 64.75px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 high 557 557 |(% style="width:99px" %)0XFE |(% style="width:112px" %)0X03|(% style="width:135px" %)0X00|(% style="width:126px" %)0X50|(% style="width:85px" %)0X00|(% style="width:1px" %)0X00|(% style="width:1px" %)0X51|(% style="width:1px" %)0XD4 558 558 562 + 559 559 **response:** 560 560 561 561 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) ... ... @@ -562,6 +562,7 @@ 562 562 |=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 563 563 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 564 564 569 + 565 565 === 3.6.2 Change address === 566 566 567 567 ... ... @@ -599,6 +599,7 @@ 599 599 0X96 600 600 ))) 601 601 607 + 602 602 === 3.6.4 Query data === 603 603 604 604 ... ... @@ -651,11 +651,11 @@ 651 651 == 4.1 Specification == 652 652 653 653 654 -* **Measuring range**: 0-20mg/L, 0 –50℃660 +* **Measuring range**: 0-20mg/L, 0-50°C 655 655 656 -* **Accuracy**: 3%, ±0.5 ℃662 +* **Accuracy**: 3%, ±0.5°C 657 657 658 -* **Resolution**: 0.01 mg/L, 0.01 ℃664 +* **Resolution**: 0.01 mg/L, 0.01°C 659 659 660 660 * **Maximum operating pressure**: 6 bar 661 661 ... ... @@ -663,9 +663,7 @@ 663 663 664 664 * **Power supply voltage**: 5-24V DC 665 665 666 -* **Working environment:** 667 -** Ambient Temperature: 0–60°C 668 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 672 +* **Working environment**: temperature 0-60°C; humidity <95%RH 669 669 670 670 * **Power consumption**: ≤0.5W 671 671 ... ... @@ -678,10 +678,13 @@ 678 678 == 4.3 Impedance requirements for current signals == 679 679 680 680 681 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:40 0px" %)682 -|(% style="width:1 32px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**683 -|(% style="width:13 2px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**685 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 686 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 687 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 684 684 689 +[[image:image-20240718195414-8.png||height="100" width="575"]] 690 + 691 + 685 685 == 4.4 Mechinical Drawing == 686 686 687 687 ... ... @@ -695,6 +695,7 @@ 695 695 696 696 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 697 697 705 + 698 698 == 4.6 RS485 Commands == 699 699 700 700 ... ... @@ -738,6 +738,7 @@ 738 738 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 739 739 |(% style="width:99px" %)0X01|(% style="width:72px" %)0X10|(% style="width:64px" %)0X00|(% style="width:68px" %)0X0A|(% style="width:70px" %)0X00|(% style="width:72px" %)0X02|(% style="width:56px" %)0X61|(% style="width:56px" %)0XCA 740 740 749 + 741 741 === 4.6.3 Query data === 742 742 743 743 ... ... @@ -780,7 +780,7 @@ 780 780 == 5.1 Specification == 781 781 782 782 783 -* **Measuring range**: 0.1 ~~1000.0NTU792 +* **Measuring range**: 0.11000.0NTU 784 784 785 785 * **Accuracy**: ±5% 786 786 ... ... @@ -788,13 +788,11 @@ 788 788 789 789 * **Stability**: ≤3mV/24 hours 790 790 791 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 800 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 792 792 793 -* **Power supply voltage**: 5 ~~24V DC (when output signal is RS485),12~~24V DC (when output signal is 4~~20mA)802 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 794 794 795 -* **Working environment:** 796 -** Ambient Temperature: 0–60°C 797 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 804 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 798 798 799 799 * **Power consumption**: ≤ 0.5W 800 800 ... ... @@ -807,10 +807,11 @@ 807 807 == 5.3 Impedance requirements for current signals == 808 808 809 809 810 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:40 0px" %)811 -|(% style="width:1 32px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**812 -|(% style="width:13 2px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**817 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 818 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 819 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 813 813 821 + 814 814 == 5.4 Mechinical Drawing == 815 815 816 816 ... ... @@ -883,9 +883,3 @@ 883 883 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 884 884 885 885 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 886 - 887 - 888 -= 6. Water Quality Sensor Datasheet = 889 - 890 - 891 -* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.4 KB - Content
- image-20241129142314-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.2 MB - Content