Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/16 09:59
From version 59.3
edited by Karry Zhuang
on 2025/07/15 14:49
on 2025/07/15 14:49
Change comment:
There is no comment for this version
To version 57.1
edited by Karry Zhuang
on 2024/12/30 10:09
on 2024/12/30 10:09
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,14 +21,9 @@ 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 22 ** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 25 25 26 26 * **EC Accuracy**: ±1% FS 27 27 * **Temperature Accuracy: **±0.5 °C 28 -* **Working environment:** 29 -** Ambient Temperature: 0–60°C 30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 -** ECK200.0 32 32 * **IP Rated**: IP68 33 33 34 34 * **Max Pressure**: 0.6MPa ... ... @@ -269,9 +269,7 @@ 269 269 270 270 * **Temperature measurement error**: ±0.5°C 271 271 272 -* **Working environment:** 273 -** Ambient Temperature: 0–60°C 274 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 267 +* **Temperature Measure Range**: -20 ~~ 60 °C 275 275 276 276 * **Temperature Accuracy: **±0.5 °C 277 277 ... ... @@ -478,9 +478,7 @@ 478 478 479 479 * **Stability**: ≤2mv/24 hours 480 480 481 -* **Working environment:** 482 -** Ambient Temperature: 0–60°C 483 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 474 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 484 484 485 485 * **IP Rated**: IP68 486 486 ... ... @@ -651,11 +651,11 @@ 651 651 == 4.1 Specification == 652 652 653 653 654 -* **Measuring range**: 0-20mg/L , 0–50℃645 +* **Measuring range**: 0-20mg/L 655 655 656 -* **Accuracy**: 3% , ±0.5℃647 +* **Accuracy**: 3% 657 657 658 -* **Resolution**: 0.01 mg/L , 0.01℃649 +* **Resolution**: 0.01 mg/L 659 659 660 660 * **Maximum operating pressure**: 6 bar 661 661 ... ... @@ -663,9 +663,7 @@ 663 663 664 664 * **Power supply voltage**: 5-24V DC 665 665 666 -* **Working environment:** 667 -** Ambient Temperature: 0–60°C 668 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 657 +* **Working environment**: temperature 0-60°C; humidity <95%RH 669 669 670 670 * **Power consumption**: ≤0.5W 671 671 ... ... @@ -792,9 +792,7 @@ 792 792 793 793 * **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 794 794 795 -* **Working environment:** 796 -** Ambient Temperature: 0–60°C 797 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 784 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 798 798 799 799 * **Power consumption**: ≤ 0.5W 800 800