Changes for page Water Quality Sensors

Last modified by Karry Zhuang on 2025/07/16 09:59

From version 59.2
edited by Karry Zhuang
on 2025/07/15 14:48
Change comment: There is no comment for this version
To version 57.1
edited by Karry Zhuang
on 2024/12/30 10:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -21,13 +21,9 @@
21 21  ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm
22 22  ** **ECK1.0** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 23  ** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm  Resolution: 1 μS/cm
25 25  
26 26  * **EC Accuracy**: ±1% FS
27 27  * **Temperature Accuracy: **±0.5 °C
28 -* **Working environment:**
29 -** Ambient Temperature: 0–60°C
30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
31 31  * **IP Rated**: IP68
32 32  
33 33  * **Max Pressure**: 0.6MPa
... ... @@ -268,9 +268,7 @@
268 268  
269 269  * **Temperature measurement error**: ±0.5°C
270 270  
271 -* **Working environment:**
272 -** Ambient Temperature: 0–60°C
273 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
267 +* **Temperature Measure Range**: -20 ~~ 60 °C
274 274  
275 275  * **Temperature Accuracy: **±0.5 °C
276 276  
... ... @@ -477,9 +477,7 @@
477 477  
478 478  * **Stability**: ≤2mv/24 hours
479 479  
480 -* **Working environment:**
481 -** Ambient Temperature: 0–60°C
482 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
474 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH
483 483  
484 484  * **IP Rated**: IP68
485 485  
... ... @@ -650,11 +650,11 @@
650 650  == 4.1 Specification ==
651 651  
652 652  
653 -* **Measuring range**: 0-20mg/L, 0–50℃
645 +* **Measuring range**: 0-20mg/L
654 654  
655 -* **Accuracy**: 3%, ±0.5℃
647 +* **Accuracy**: 3%
656 656  
657 -* **Resolution**: 0.01 mg/L, 0.01℃
649 +* **Resolution**: 0.01 mg/L
658 658  
659 659  * **Maximum operating pressure**: 6 bar
660 660  
... ... @@ -662,9 +662,7 @@
662 662  
663 663  * **Power supply voltage**: 5-24V DC
664 664  
665 -* **Working environment:**
666 -** Ambient Temperature: 0–60°C
667 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
657 +* **Working environment**: temperature 0-60°C; humidity <95%RH
668 668  
669 669  * **Power consumption**: ≤0.5W
670 670  
... ... @@ -791,9 +791,7 @@
791 791  
792 792  * **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA)
793 793  
794 -* **Working environment:**
795 -** Ambient Temperature: 0–60°C
796 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
784 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH
797 797  
798 798  * **Power consumption**: ≤ 0.5W
799 799