... ... @@ -19,15 +19,15 @@
19 19  * **EC Range & Resolution:**
20 20  ** **ECK0.01** : 0.02 ~~ 20 μS/cm
21 21  ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm
22 -** **ECK1.0** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 -** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm  Resolution: 1 μS/cm
22 +** **ECK1.0** : 2 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 +** **ECK10.0** : 20 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
25 25  
26 26  * **EC Accuracy**: ±1% FS
26 +
27 +* **Temperature Measure Range**: -20 ~~ 60 °C
28 +
27 27  * **Temperature Accuracy: **±0.5 °C
28 -* **Working environment:**
29 -** Ambient Temperature: 0–60°C
30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
30 +
31 31  * **IP Rated**: IP68
32 32  
33 33  * **Max Pressure**: 0.6MPa
... ... @@ -41,7 +41,7 @@
41 41  == 1.3 Wiring ==
42 42  
43 43  
44 -[[image:image-20241129142314-1.png||height="352" width="1108"]]
44 +[[image:image-20240720172533-1.png||height="347" width="569"]]
45 45  
46 46  
47 47  == 1.4 Mechinical Drawing ==
... ... @@ -268,9 +268,7 @@
268 268  
269 269  * **Temperature measurement error**: ±0.5°C
270 270  
271 -* **Working environment:**
272 -** Ambient Temperature: 0–60°C
273 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
271 +* **Temperature Measure Range**: -20 ~~ 60 °C
274 274  
275 275  * **Temperature Accuracy: **±0.5 °C
276 276  
... ... @@ -477,9 +477,7 @@
477 477  
478 478  * **Stability**: ≤2mv/24 hours
479 479  
480 -* **Working environment:**
481 -** Ambient Temperature: 0–60°C
482 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
478 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH
483 483  
484 484  * **IP Rated**: IP68
485 485  
... ... @@ -561,6 +561,7 @@
561 561  |=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high
562 562  |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0
563 563  
560 +
564 564  === 3.6.2 Change address ===
565 565  
566 566  
... ... @@ -645,16 +645,17 @@
645 645  0XC3
646 646  )))
647 647  
645 +
648 648  = 4. DR-DO1 Dissolved Oxygen Sensor =
649 649  
650 650  == 4.1 Specification ==
651 651  
652 652  
653 -* **Measuring range**: 0-20mg/L, 050
651 +* **Measuring range**: 0-20mg/L, 0-50°C
654 654  
655 -* **Accuracy**: 3%, ±0.5
653 +* **Accuracy**: 3%, ±0.5°C
656 656  
657 -* **Resolution**: 0.01 mg/L, 0.01
655 +* **Resolution**: 0.01 mg/L, 0.01°C
658 658  
659 659  * **Maximum operating pressure**: 6 bar
660 660  
... ... @@ -662,12 +662,11 @@
662 662  
663 663  * **Power supply voltage**: 5-24V DC
664 664  
665 -* **Working environment:**
666 -** Ambient Temperature: 0–60°C
667 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
663 +* **Working environment**: temperature 0-60°C; humidity <95%RH
668 668  
669 669  * **Power consumption**: ≤0.5W
670 670  
667 +
671 671  == 4.2 wiring ==
672 672  
673 673  
... ... @@ -681,6 +681,7 @@
681 681  |(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
682 682  |(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
683 683  
681 +
684 684  == 4.4 Mechinical Drawing ==
685 685  
686 686  
... ... @@ -694,6 +694,7 @@
694 694  
695 695  * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently.
696 696  
695 +
697 697  == 4.6 RS485 Commands ==
698 698  
699 699  
... ... @@ -779,7 +779,7 @@
779 779  == 5.1 Specification ==
780 780  
781 781  
782 -* **Measuring range**: 0.1~~1000.0NTU
781 +* **Measuring range**: 0.11000.0NTU
783 783  
784 784  * **Accuracy**: ±5%
785 785  
... ... @@ -787,13 +787,11 @@
787 787  
788 788  * **Stability**: ≤3mV/24 hours
789 789  
790 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01)
789 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01)
791 791  
792 -* **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA)
791 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA)
793 793  
794 -* **Working environment:**
795 -** Ambient Temperature: 0–60°C
796 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
793 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH
797 797  
798 798  * **Power consumption**: ≤ 0.5W
799 799  
... ... @@ -810,6 +810,7 @@
810 810  |(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
811 811  |(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
812 812  
810 +
813 813  == 5.4 Mechinical Drawing ==
814 814  
815 815  
... ... @@ -823,6 +823,7 @@
823 823  
824 824  * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently.
825 825  
824 +
826 826  == 5.6 RS485 Commands ==
827 827  
828 828  
... ... @@ -882,9 +882,3 @@
882 882  For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C
883 883  
884 884  02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU
885 -
886 -
887 -= 6.  Water Quality Sensor Datasheet =
888 -
889 -
890 -* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
image-20241129142314-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -1.2 MB
Content