Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
From version 59.1
edited by Karry Zhuang
on 2025/02/18 15:43
on 2025/02/18 15:43
Change comment:
There is no comment for this version
To version 57.1
edited by Karry Zhuang
on 2024/12/30 10:09
on 2024/12/30 10:09
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -24,9 +24,6 @@ 24 24 25 25 * **EC Accuracy**: ±1% FS 26 26 * **Temperature Accuracy: **±0.5 °C 27 -* **Working environment:** 28 -** Ambient Temperature: 0–60°C 29 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 30 30 * **IP Rated**: IP68 31 31 32 32 * **Max Pressure**: 0.6MPa ... ... @@ -267,9 +267,7 @@ 267 267 268 268 * **Temperature measurement error**: ±0.5°C 269 269 270 -* **Working environment:** 271 -** Ambient Temperature: 0–60°C 272 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 267 +* **Temperature Measure Range**: -20 ~~ 60 °C 273 273 274 274 * **Temperature Accuracy: **±0.5 °C 275 275 ... ... @@ -476,9 +476,7 @@ 476 476 477 477 * **Stability**: ≤2mv/24 hours 478 478 479 -* **Working environment:** 480 -** Ambient Temperature: 0–60°C 481 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 474 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 482 482 483 483 * **IP Rated**: IP68 484 484 ... ... @@ -649,11 +649,11 @@ 649 649 == 4.1 Specification == 650 650 651 651 652 -* **Measuring range**: 0-20mg/L , 0–50℃645 +* **Measuring range**: 0-20mg/L 653 653 654 -* **Accuracy**: 3% , ±0.5℃647 +* **Accuracy**: 3% 655 655 656 -* **Resolution**: 0.01 mg/L , 0.01℃649 +* **Resolution**: 0.01 mg/L 657 657 658 658 * **Maximum operating pressure**: 6 bar 659 659 ... ... @@ -661,9 +661,7 @@ 661 661 662 662 * **Power supply voltage**: 5-24V DC 663 663 664 -* **Working environment:** 665 -** Ambient Temperature: 0–60°C 666 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 657 +* **Working environment**: temperature 0-60°C; humidity <95%RH 667 667 668 668 * **Power consumption**: ≤0.5W 669 669 ... ... @@ -790,9 +790,7 @@ 790 790 791 791 * **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 792 792 793 -* **Working environment:** 794 -** Ambient Temperature: 0–60°C 795 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 784 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 796 796 797 797 * **Power consumption**: ≤ 0.5W 798 798