Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,10 +23,11 @@ 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 + 27 +* **Temperature Measure Range**: -20 ~~ 60 °C 28 + 26 26 * **Temperature Accuracy: **±0.5 °C 27 -* **Working environment:** 28 -** Ambient Temperature: 0–60°C 29 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 30 + 30 30 * **IP Rated**: IP68 31 31 32 32 * **Max Pressure**: 0.6MPa ... ... @@ -40,7 +40,7 @@ 40 40 == 1.3 Wiring == 41 41 42 42 43 -[[image:image-20241129142314-1.png ||height="352" width="1108"]]44 +[[image:image-20241129142314-1.png]] 44 44 45 45 46 46 == 1.4 Mechinical Drawing == ... ... @@ -267,9 +267,7 @@ 267 267 268 268 * **Temperature measurement error**: ±0.5°C 269 269 270 -* **Working environment:** 271 -** Ambient Temperature: 0–60°C 272 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 271 +* **Temperature Measure Range**: -20 ~~ 60 °C 273 273 274 274 * **Temperature Accuracy: **±0.5 °C 275 275 ... ... @@ -476,9 +476,7 @@ 476 476 477 477 * **Stability**: ≤2mv/24 hours 478 478 479 -* **Working environment:** 480 -** Ambient Temperature: 0–60°C 481 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 478 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 482 482 483 483 * **IP Rated**: IP68 484 484 ... ... @@ -649,11 +649,11 @@ 649 649 == 4.1 Specification == 650 650 651 651 652 -* **Measuring range**: 0-20mg/L, 0 –50℃649 +* **Measuring range**: 0-20mg/L, 0-50°C 653 653 654 -* **Accuracy**: 3%, ±0.5 ℃651 +* **Accuracy**: 3%, ±0.5°C 655 655 656 -* **Resolution**: 0.01 mg/L, 0.01 ℃653 +* **Resolution**: 0.01 mg/L, 0.01°C 657 657 658 658 * **Maximum operating pressure**: 6 bar 659 659 ... ... @@ -661,9 +661,7 @@ 661 661 662 662 * **Power supply voltage**: 5-24V DC 663 663 664 -* **Working environment:** 665 -** Ambient Temperature: 0–60°C 666 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 661 +* **Working environment**: temperature 0-60°C; humidity <95%RH 667 667 668 668 * **Power consumption**: ≤0.5W 669 669 ... ... @@ -786,13 +786,11 @@ 786 786 787 787 * **Stability**: ≤3mV/24 hours 788 788 789 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 784 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 790 790 791 -* **Power supply voltage**: 5 ~~24V DC (when output signal is RS485),12~~24V DC (when output signal is 4~~20mA)786 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 792 792 793 -* **Working environment:** 794 -** Ambient Temperature: 0–60°C 795 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 788 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 796 796 797 797 * **Power consumption**: ≤ 0.5W 798 798 ... ... @@ -887,3 +887,4 @@ 887 887 888 888 889 889 * **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]** 883 +