Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
<
edited by Karry Zhuang
on 2025/02/18 15:43
on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. karry1 +XWiki.Xiaoling - Content
-
... ... @@ -19,14 +19,15 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 0~~ 2,000 μS/cm Resolution: 1 μS/cm23 -** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm22 +** **ECK1.0** : 2 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 + 27 +* **Temperature Measure Range**: -20 ~~ 60 °C 28 + 26 26 * **Temperature Accuracy: **±0.5 °C 27 -* **Working environment:** 28 -** Ambient Temperature: 0–60°C 29 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 30 + 30 30 * **IP Rated**: IP68 31 31 32 32 * **Max Pressure**: 0.6MPa ... ... @@ -40,7 +40,7 @@ 40 40 == 1.3 Wiring == 41 41 42 42 43 -[[image:image-2024 1129142314-1.png||height="352" width="1108"]]44 +[[image:image-20240720172533-1.png||height="347" width="569"]] 44 44 45 45 46 46 == 1.4 Mechinical Drawing == ... ... @@ -267,9 +267,7 @@ 267 267 268 268 * **Temperature measurement error**: ±0.5°C 269 269 270 -* **Working environment:** 271 -** Ambient Temperature: 0–60°C 272 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 271 +* **Temperature Measure Range**: -20 ~~ 60 °C 273 273 274 274 * **Temperature Accuracy: **±0.5 °C 275 275 ... ... @@ -476,9 +476,7 @@ 476 476 477 477 * **Stability**: ≤2mv/24 hours 478 478 479 -* **Working environment:** 480 -** Ambient Temperature: 0–60°C 481 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 478 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 482 482 483 483 * **IP Rated**: IP68 484 484 ... ... @@ -560,6 +560,7 @@ 560 560 |=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 561 561 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 562 562 560 + 563 563 === 3.6.2 Change address === 564 564 565 565 ... ... @@ -644,16 +644,17 @@ 644 644 0XC3 645 645 ))) 646 646 645 + 647 647 = 4. DR-DO1 Dissolved Oxygen Sensor = 648 648 649 649 == 4.1 Specification == 650 650 651 651 652 -* **Measuring range**: 0-20mg/L, 0 –50℃651 +* **Measuring range**: 0-20mg/L, 0-50°C 653 653 654 -* **Accuracy**: 3%, ±0.5 ℃653 +* **Accuracy**: 3%, ±0.5°C 655 655 656 -* **Resolution**: 0.01 mg/L, 0.01 ℃655 +* **Resolution**: 0.01 mg/L, 0.01°C 657 657 658 658 * **Maximum operating pressure**: 6 bar 659 659 ... ... @@ -661,12 +661,11 @@ 661 661 662 662 * **Power supply voltage**: 5-24V DC 663 663 664 -* **Working environment:** 665 -** Ambient Temperature: 0–60°C 666 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 663 +* **Working environment**: temperature 0-60°C; humidity <95%RH 667 667 668 668 * **Power consumption**: ≤0.5W 669 669 667 + 670 670 == 4.2 wiring == 671 671 672 672 ... ... @@ -680,6 +680,7 @@ 680 680 |(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 681 681 |(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 682 682 681 + 683 683 == 4.4 Mechinical Drawing == 684 684 685 685 ... ... @@ -693,6 +693,7 @@ 693 693 694 694 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 695 695 695 + 696 696 == 4.6 RS485 Commands == 697 697 698 698 ... ... @@ -778,7 +778,7 @@ 778 778 == 5.1 Specification == 779 779 780 780 781 -* **Measuring range**: 0.1 ~~1000.0NTU781 +* **Measuring range**: 0.11000.0NTU 782 782 783 783 * **Accuracy**: ±5% 784 784 ... ... @@ -786,13 +786,11 @@ 786 786 787 787 * **Stability**: ≤3mV/24 hours 788 788 789 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 789 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 790 790 791 -* **Power supply voltage**: 5 ~~24V DC (when output signal is RS485),12~~24V DC (when output signal is 4~~20mA)791 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 792 792 793 -* **Working environment:** 794 -** Ambient Temperature: 0–60°C 795 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 793 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 796 796 797 797 * **Power consumption**: ≤ 0.5W 798 798 ... ... @@ -809,6 +809,7 @@ 809 809 |(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 810 810 |(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 811 811 810 + 812 812 == 5.4 Mechinical Drawing == 813 813 814 814 ... ... @@ -822,6 +822,7 @@ 822 822 823 823 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 824 824 824 + 825 825 == 5.6 RS485 Commands == 826 826 827 827 ... ... @@ -881,9 +881,3 @@ 881 881 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 882 882 883 883 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 884 - 885 - 886 -= 6. Water Quality Sensor Datasheet = 887 - 888 - 889 -* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
- image-20241129142314-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.2 MB - Content