Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/16 09:59
From version 56.1
edited by Karry Zhuang
on 2024/12/24 09:55
on 2024/12/24 09:55
Change comment:
There is no comment for this version
To version 59.2
edited by Karry Zhuang
on 2025/07/15 14:48
on 2025/07/15 14:48
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,9 +21,13 @@ 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 22 ** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 +** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 26 * **Temperature Accuracy: **±0.5 °C 28 +* **Working environment:** 29 +** Ambient Temperature: 0–60°C 30 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 27 27 * **IP Rated**: IP68 28 28 29 29 * **Max Pressure**: 0.6MPa ... ... @@ -264,7 +264,9 @@ 264 264 265 265 * **Temperature measurement error**: ±0.5°C 266 266 267 -* **Temperature Measure Range**: -20 ~~ 60 °C 271 +* **Working environment:** 272 +** Ambient Temperature: 0–60°C 273 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 268 268 269 269 * **Temperature Accuracy: **±0.5 °C 270 270 ... ... @@ -471,7 +471,9 @@ 471 471 472 472 * **Stability**: ≤2mv/24 hours 473 473 474 -* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 480 +* **Working environment:** 481 +** Ambient Temperature: 0–60°C 482 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 475 475 476 476 * **IP Rated**: IP68 477 477 ... ... @@ -642,11 +642,11 @@ 642 642 == 4.1 Specification == 643 643 644 644 645 -* **Measuring range**: 0-20mg/L, 0 -50°C653 +* **Measuring range**: 0-20mg/L, 0–50℃ 646 646 647 -* **Accuracy**: 3%, ±0.5 °C655 +* **Accuracy**: 3%, ±0.5℃ 648 648 649 -* **Resolution**: 0.01 mg/L, 0.01 °C657 +* **Resolution**: 0.01 mg/L, 0.01℃ 650 650 651 651 * **Maximum operating pressure**: 6 bar 652 652 ... ... @@ -654,7 +654,9 @@ 654 654 655 655 * **Power supply voltage**: 5-24V DC 656 656 657 -* **Working environment**: temperature 0-60°C; humidity <95%RH 665 +* **Working environment:** 666 +** Ambient Temperature: 0–60°C 667 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 658 658 659 659 * **Power consumption**: ≤0.5W 660 660 ... ... @@ -781,7 +781,9 @@ 781 781 782 782 * **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 783 783 784 -* **Working environment**: temperature 060°C; humidity ≤ 95%RH 794 +* **Working environment:** 795 +** Ambient Temperature: 0–60°C 796 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 785 785 786 786 * **Power consumption**: ≤ 0.5W 787 787