Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. karry1 +XWiki.Xiaoling - Content
-
... ... @@ -19,11 +19,15 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 0~~ 2,000 μS/cm Resolution: 1 μS/cm23 -** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm22 +** **ECK1.0** : 2 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 + 27 +* **Temperature Measure Range**: -20 ~~ 60 °C 28 + 26 26 * **Temperature Accuracy: **±0.5 °C 30 + 27 27 * **IP Rated**: IP68 28 28 29 29 * **Max Pressure**: 0.6MPa ... ... @@ -37,7 +37,7 @@ 37 37 == 1.3 Wiring == 38 38 39 39 40 -[[image:image-2024 1129142314-1.png||height="352" width="1108"]]44 +[[image:image-20240720172533-1.png||height="347" width="569"]] 41 41 42 42 43 43 == 1.4 Mechinical Drawing == ... ... @@ -637,6 +637,7 @@ 637 637 0XC3 638 638 ))) 639 639 644 + 640 640 = 4. DR-DO1 Dissolved Oxygen Sensor = 641 641 642 642 == 4.1 Specification == ... ... @@ -667,10 +667,9 @@ 667 667 == 4.3 Impedance requirements for current signals == 668 668 669 669 670 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %) 671 -|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 672 -|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 675 +[[image:image-20240718195414-8.png||height="100" width="575"]] 673 673 677 + 674 674 == 4.4 Mechinical Drawing == 675 675 676 676 ... ... @@ -769,7 +769,7 @@ 769 769 == 5.1 Specification == 770 770 771 771 772 -* **Measuring range**: 0.1 ~~1000.0NTU776 +* **Measuring range**: 0.11000.0NTU 773 773 774 774 * **Accuracy**: ±5% 775 775 ... ... @@ -777,9 +777,9 @@ 777 777 778 778 * **Stability**: ≤3mV/24 hours 779 779 780 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 784 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 781 781 782 -* **Power supply voltage**: 5 ~~24V DC (when output signal is RS485),12~~24V DC (when output signal is 4~~20mA)786 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 783 783 784 784 * **Working environment**: temperature 060°C; humidity ≤ 95%RH 785 785 ... ... @@ -794,10 +794,11 @@ 794 794 == 5.3 Impedance requirements for current signals == 795 795 796 796 797 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:40 0px" %)798 -|(% style="width:1 32px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**799 -|(% style="width:13 2px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**801 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 802 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 803 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 800 800 805 + 801 801 == 5.4 Mechinical Drawing == 802 802 803 803 ... ... @@ -870,9 +870,3 @@ 870 870 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 871 871 872 872 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 873 - 874 - 875 -= 6. Water Quality Sensor Datasheet = 876 - 877 - 878 -* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
- image-20241129142314-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.2 MB - Content