Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 55.1
edited by Xiaoling
on 2024/12/21 11:04
on 2024/12/21 11:04
Change comment:
There is no comment for this version
To version 60.5
edited by Karry Zhuang
on 2025/07/15 15:34
on 2025/07/15 15:34
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.karry - Content
-
... ... @@ -21,13 +21,14 @@ 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 22 ** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 +** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 - 27 -* **Temperature Measure Range**: -20 ~~ 60 °C 28 - 29 29 * **Temperature Accuracy: **±0.5 °C 30 - 28 +* **Working environment:** 29 +** Ambient Temperature: 0–60°C 30 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 +** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 31 31 * **IP Rated**: IP68 32 32 33 33 * **Max Pressure**: 0.6MPa ... ... @@ -46,10 +46,12 @@ 46 46 47 47 == 1.4 Mechinical Drawing == 48 48 50 + ECK1 and ECK10 ECK200 49 49 50 -[[image:image-20240714174241-2.png]] 51 51 53 +[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] 52 52 55 + 53 53 == 1.5 Installation == 54 54 55 55 ... ... @@ -268,7 +268,9 @@ 268 268 269 269 * **Temperature measurement error**: ±0.5°C 270 270 271 -* **Temperature Measure Range**: -20 ~~ 60 °C 274 +* **Working environment:** 275 +** Ambient Temperature: 0–60°C 276 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 272 272 273 273 * **Temperature Accuracy: **±0.5 °C 274 274 ... ... @@ -475,7 +475,9 @@ 475 475 476 476 * **Stability**: ≤2mv/24 hours 477 477 478 -* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 483 +* **Working environment:** 484 +** Ambient Temperature: 0–60°C 485 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 479 479 480 480 * **IP Rated**: IP68 481 481 ... ... @@ -646,11 +646,11 @@ 646 646 == 4.1 Specification == 647 647 648 648 649 -* **Measuring range**: 0-20mg/L, 0 -50°C656 +* **Measuring range**: 0-20mg/L, 0–50℃ 650 650 651 -* **Accuracy**: 3%, ±0.5 °C658 +* **Accuracy**: 3%, ±0.5℃ 652 652 653 -* **Resolution**: 0.01 mg/L, 0.01 °C660 +* **Resolution**: 0.01 mg/L, 0.01℃ 654 654 655 655 * **Maximum operating pressure**: 6 bar 656 656 ... ... @@ -658,7 +658,9 @@ 658 658 659 659 * **Power supply voltage**: 5-24V DC 660 660 661 -* **Working environment**: temperature 0-60°C; humidity <95%RH 668 +* **Working environment:** 669 +** Ambient Temperature: 0–60°C 670 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 662 662 663 663 * **Power consumption**: ≤0.5W 664 664 ... ... @@ -785,7 +785,9 @@ 785 785 786 786 * **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 787 787 788 -* **Working environment**: temperature 060°C; humidity ≤ 95%RH 797 +* **Working environment:** 798 +** Ambient Temperature: 0–60°C 799 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 789 789 790 790 * **Power consumption**: ≤ 0.5W 791 791
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +144.4 KB - Content