Changes for page Water Quality Sensors

Last modified by Karry Zhuang on 2025/02/18 15:43

From version 55.1
edited by Xiaoling
on 2024/12/21 11:04
Change comment: There is no comment for this version
To version 59.1
edited by Karry Zhuang
on 2025/02/18 15:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.karry
Content
... ... @@ -23,11 +23,10 @@
23 23  ** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
24 24  
25 25  * **EC Accuracy**: ±1% FS
26 -
27 -* **Temperature Measure Range**: -20 ~~ 60 °C
28 -
29 29  * **Temperature Accuracy: **±0.5 °C
30 -
27 +* **Working environment:**
28 +** Ambient Temperature: 0–60°C
29 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
31 31  * **IP Rated**: IP68
32 32  
33 33  * **Max Pressure**: 0.6MPa
... ... @@ -268,7 +268,9 @@
268 268  
269 269  * **Temperature measurement error**: ±0.5°C
270 270  
271 -* **Temperature Measure Range**: -20 ~~ 60 °C
270 +* **Working environment:**
271 +** Ambient Temperature: 0–60°C
272 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
272 272  
273 273  * **Temperature Accuracy: **±0.5 °C
274 274  
... ... @@ -475,7 +475,9 @@
475 475  
476 476  * **Stability**: ≤2mv/24 hours
477 477  
478 -* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH
479 +* **Working environment:**
480 +** Ambient Temperature: 0–60°C
481 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
479 479  
480 480  * **IP Rated**: IP68
481 481  
... ... @@ -646,11 +646,11 @@
646 646  == 4.1 Specification ==
647 647  
648 648  
649 -* **Measuring range**: 0-20mg/L, 0-50°C
652 +* **Measuring range**: 0-20mg/L, 050
650 650  
651 -* **Accuracy**: 3%, ±0.5°C
654 +* **Accuracy**: 3%, ±0.5
652 652  
653 -* **Resolution**: 0.01 mg/L, 0.01°C
656 +* **Resolution**: 0.01 mg/L, 0.01
654 654  
655 655  * **Maximum operating pressure**: 6 bar
656 656  
... ... @@ -658,7 +658,9 @@
658 658  
659 659  * **Power supply voltage**: 5-24V DC
660 660  
661 -* **Working environment**: temperature 0-60°C; humidity <95%RH
664 +* **Working environment:**
665 +** Ambient Temperature: 0–60°C
666 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
662 662  
663 663  * **Power consumption**: ≤0.5W
664 664  
... ... @@ -785,7 +785,9 @@
785 785  
786 786  * **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA)
787 787  
788 -* **Working environment**: temperature 060°C; humidity ≤ 95%RH
793 +* **Working environment:**
794 +** Ambient Temperature: 0–60°C
795 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female)
789 789  
790 790  * **Power consumption**: ≤ 0.5W
791 791