Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
From version 54.1
edited by Karry Zhuang
on 2024/12/21 09:35
on 2024/12/21 09:35
Change comment:
There is no comment for this version
To version 56.1
edited by Karry Zhuang
on 2024/12/24 09:55
on 2024/12/24 09:55
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,11 +23,7 @@ 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 - 27 -* **Temperature Measure Range**: -20 ~~ 60 °C 28 - 29 29 * **Temperature Accuracy: **±0.5 °C 30 - 31 31 * **IP Rated**: IP68 32 32 33 33 * **Max Pressure**: 0.6MPa ... ... @@ -41,7 +41,7 @@ 41 41 == 1.3 Wiring == 42 42 43 43 44 -[[image:image-20241129142314-1.png]] 40 +[[image:image-20241129142314-1.png||height="352" width="1108"]] 45 45 46 46 47 47 == 1.4 Mechinical Drawing == ... ... @@ -783,7 +783,7 @@ 783 783 784 784 * **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 785 785 786 -* **Power supply voltage**: 524V DC (when output signal is RS485)12 -24V DC (when output signal is 420mA)782 +* **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 787 787 788 788 * **Working environment**: temperature 060°C; humidity ≤ 95%RH 789 789