Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
From version 53.1
edited by Karry Zhuang
on 2024/11/29 14:23
on 2024/11/29 14:23
Change comment:
There is no comment for this version
To version 59.1
edited by Karry Zhuang
on 2025/02/18 15:43
on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,11 +23,10 @@ 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 - 27 -* **Temperature Measure Range**: -20 ~~ 60 °C 28 - 29 29 * **Temperature Accuracy: **±0.5 °C 30 - 27 +* **Working environment:** 28 +** Ambient Temperature: 0–60°C 29 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 31 * **IP Rated**: IP68 32 32 33 33 * **Max Pressure**: 0.6MPa ... ... @@ -41,7 +41,7 @@ 41 41 == 1.3 Wiring == 42 42 43 43 44 -[[image:image-20241129142314-1.png]] 43 +[[image:image-20241129142314-1.png||height="352" width="1108"]] 45 45 46 46 47 47 == 1.4 Mechinical Drawing == ... ... @@ -268,7 +268,9 @@ 268 268 269 269 * **Temperature measurement error**: ±0.5°C 270 270 271 -* **Temperature Measure Range**: -20 ~~ 60 °C 270 +* **Working environment:** 271 +** Ambient Temperature: 0–60°C 272 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 272 272 273 273 * **Temperature Accuracy: **±0.5 °C 274 274 ... ... @@ -475,7 +475,9 @@ 475 475 476 476 * **Stability**: ≤2mv/24 hours 477 477 478 -* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 479 +* **Working environment:** 480 +** Ambient Temperature: 0–60°C 481 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 479 479 480 480 * **IP Rated**: IP68 481 481 ... ... @@ -646,11 +646,11 @@ 646 646 == 4.1 Specification == 647 647 648 648 649 -* **Measuring range**: 0-20mg/L, 0 -50°C652 +* **Measuring range**: 0-20mg/L, 0–50℃ 650 650 651 -* **Accuracy**: 3%, ±0.5 °C654 +* **Accuracy**: 3%, ±0.5℃ 652 652 653 -* **Resolution**: 0.01 mg/L, 0.01 °C656 +* **Resolution**: 0.01 mg/L, 0.01℃ 654 654 655 655 * **Maximum operating pressure**: 6 bar 656 656 ... ... @@ -658,7 +658,9 @@ 658 658 659 659 * **Power supply voltage**: 5-24V DC 660 660 661 -* **Working environment**: temperature 0-60°C; humidity <95%RH 664 +* **Working environment:** 665 +** Ambient Temperature: 0–60°C 666 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 662 662 663 663 * **Power consumption**: ≤0.5W 664 664 ... ... @@ -781,11 +781,13 @@ 781 781 782 782 * **Stability**: ≤3mV/24 hours 783 783 784 -* **Output signal**: A: 420 mA (current loop)B:RS485 (standard Modbus-RTU protocol, device default address: 01)789 +* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 785 785 786 -* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 791 +* **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 787 787 788 -* **Working environment**: temperature 060°C; humidity ≤ 95%RH 793 +* **Working environment:** 794 +** Ambient Temperature: 0–60°C 795 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 789 789 790 790 * **Power consumption**: ≤ 0.5W 791 791 ... ... @@ -880,4 +880,3 @@ 880 880 881 881 882 882 * **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]** 883 -