Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,8 +19,8 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 0~~ 2,000 μS/cm Resolution: 1 μS/cm23 -** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm22 +** **ECK1.0** : 2 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 26 ... ... @@ -675,6 +675,7 @@ 675 675 |(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 676 676 |(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 677 677 678 + 678 678 == 4.4 Mechinical Drawing == 679 679 680 680 ... ... @@ -773,7 +773,7 @@ 773 773 == 5.1 Specification == 774 774 775 775 776 -* **Measuring range**: 0.1 ~~1000.0NTU777 +* **Measuring range**: 0.11000.0NTU 777 777 778 778 * **Accuracy**: ±5% 779 779 ... ... @@ -798,9 +798,9 @@ 798 798 == 5.3 Impedance requirements for current signals == 799 799 800 800 801 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:40 0px" %)802 -|(% style="width:1 32px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**803 -|(% style="width:13 2px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**802 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 803 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 804 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 804 804 805 805 == 5.4 Mechinical Drawing == 806 806 ... ... @@ -874,11 +874,3 @@ 874 874 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 875 875 876 876 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 877 - 878 - 879 -= 6. Water Quality Sensor Datasheet = 880 - 881 - 882 -* **[[WQS-xS_Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]** 883 - 884 -