... ... @@ -19,8 +19,8 @@
19 19  * **EC Range & Resolution:**
20 20  ** **ECK0.01** : 0.02 ~~ 20 μS/cm
21 21  ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm
22 -** **ECK1.0** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 -** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
22 +** **ECK1.0** : 2 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 +** **ECK10.0** : 20 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
24 24  
25 25  * **EC Accuracy**: ±1% FS
26 26  
... ... @@ -675,6 +675,7 @@
675 675  |(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
676 676  |(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
677 677  
678 +
678 678  == 4.4 Mechinical Drawing ==
679 679  
680 680  
... ... @@ -773,7 +773,7 @@
773 773  == 5.1 Specification ==
774 774  
775 775  
776 -* **Measuring range**: 0.1~~1000.0NTU
777 +* **Measuring range**: 0.11000.0NTU
777 777  
778 778  * **Accuracy**: ±5%
779 779  
... ... @@ -798,9 +798,9 @@
798 798  == 5.3 Impedance requirements for current signals ==
799 799  
800 800  
801 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %)
802 -|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
803 -|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
802 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %)
803 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V**
804 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω**
804 804  
805 805  == 5.4 Mechinical Drawing ==
806 806  
... ... @@ -874,11 +874,3 @@
874 874  For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C
875 875  
876 876  02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU
877 -
878 -
879 -= 6.  Water Quality Sensor Datasheet =
880 -
881 -
882 -* **[[WQS-xS_Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
883 -
884 -
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved