Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,11 +23,10 @@ 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 - 27 -* **Temperature Measure Range**: -20 ~~ 60 °C 28 - 29 29 * **Temperature Accuracy: **±0.5 °C 30 - 27 +* **Working environment:** 28 +** Ambient Temperature: 0–60°C 29 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 31 * **IP Rated**: IP68 32 32 33 33 * **Max Pressure**: 0.6MPa ... ... @@ -41,7 +41,7 @@ 41 41 == 1.3 Wiring == 42 42 43 43 44 -[[image:image-2024 0720172533-1.png||height="347" width="569"]]43 +[[image:image-20241129142314-1.png||height="352" width="1108"]] 45 45 46 46 47 47 == 1.4 Mechinical Drawing == ... ... @@ -268,7 +268,9 @@ 268 268 269 269 * **Temperature measurement error**: ±0.5°C 270 270 271 -* **Temperature Measure Range**: -20 ~~ 60 °C 270 +* **Working environment:** 271 +** Ambient Temperature: 0–60°C 272 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 272 272 273 273 * **Temperature Accuracy: **±0.5 °C 274 274 ... ... @@ -475,7 +475,9 @@ 475 475 476 476 * **Stability**: ≤2mv/24 hours 477 477 478 -* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 479 +* **Working environment:** 480 +** Ambient Temperature: 0–60°C 481 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 479 479 480 480 * **IP Rated**: IP68 481 481 ... ... @@ -646,11 +646,11 @@ 646 646 == 4.1 Specification == 647 647 648 648 649 -* **Measuring range**: 0-20mg/L, 0 -50°C652 +* **Measuring range**: 0-20mg/L, 0–50℃ 650 650 651 -* **Accuracy**: 3%, ±0.5 °C654 +* **Accuracy**: 3%, ±0.5℃ 652 652 653 -* **Resolution**: 0.01 mg/L, 0.01 °C656 +* **Resolution**: 0.01 mg/L, 0.01℃ 654 654 655 655 * **Maximum operating pressure**: 6 bar 656 656 ... ... @@ -658,7 +658,9 @@ 658 658 659 659 * **Power supply voltage**: 5-24V DC 660 660 661 -* **Working environment**: temperature 0-60°C; humidity <95%RH 664 +* **Working environment:** 665 +** Ambient Temperature: 0–60°C 666 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 662 662 663 663 * **Power consumption**: ≤0.5W 664 664 ... ... @@ -781,11 +781,13 @@ 781 781 782 782 * **Stability**: ≤3mV/24 hours 783 783 784 -* **Output signal**: A: 420 mA (current loop)B:RS485 (standard Modbus-RTU protocol, device default address: 01)789 +* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 785 785 786 -* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 791 +* **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 787 787 788 -* **Working environment**: temperature 060°C; humidity ≤ 95%RH 793 +* **Working environment:** 794 +** Ambient Temperature: 0–60°C 795 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 789 789 790 790 * **Power consumption**: ≤ 0.5W 791 791 ... ... @@ -874,3 +874,9 @@ 874 874 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 875 875 876 876 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 884 + 885 + 886 += 6. Water Quality Sensor Datasheet = 887 + 888 + 889 +* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
- image-20241129142314-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.2 MB - Content