Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
<
edited by Karry Zhuang
on 2025/02/18 15:43
on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.karry - Content
-
... ... @@ -19,20 +19,18 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 2~~ 2,000 μS/cm Resolution: 1 μS/cm23 -** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm22 +** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 - 27 -* **Temperature Measure Range**: -20 ~~ 60 °C 28 - 29 29 * **Temperature Accuracy: **±0.5 °C 30 - 27 +* **Working environment:** 28 +** Ambient Temperature: 0–60°C 29 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 31 * **IP Rated**: IP68 32 32 33 33 * **Max Pressure**: 0.6MPa 34 34 35 - 36 36 == 1.2 Application for Different Range == 37 37 38 38 ... ... @@ -42,7 +42,7 @@ 42 42 == 1.3 Wiring == 43 43 44 44 45 -[[image:image-2024 0720172533-1.png||height="347" width="569"]]43 +[[image:image-20241129142314-1.png||height="352" width="1108"]] 46 46 47 47 48 48 == 1.4 Mechinical Drawing == ... ... @@ -269,7 +269,9 @@ 269 269 270 270 * **Temperature measurement error**: ±0.5°C 271 271 272 -* **Temperature Measure Range**: -20 ~~ 60 °C 270 +* **Working environment:** 271 +** Ambient Temperature: 0–60°C 272 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 273 273 274 274 * **Temperature Accuracy: **±0.5 °C 275 275 ... ... @@ -476,7 +476,9 @@ 476 476 477 477 * **Stability**: ≤2mv/24 hours 478 478 479 -* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 479 +* **Working environment:** 480 +** Ambient Temperature: 0–60°C 481 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 480 480 481 481 * **IP Rated**: IP68 482 482 ... ... @@ -647,11 +647,11 @@ 647 647 == 4.1 Specification == 648 648 649 649 650 -* **Measuring range**: 0-20mg/L, 0 -50°C652 +* **Measuring range**: 0-20mg/L, 0–50℃ 651 651 652 -* **Accuracy**: 3%, ±0.5 °C654 +* **Accuracy**: 3%, ±0.5℃ 653 653 654 -* **Resolution**: 0.01 mg/L, 0.01 °C656 +* **Resolution**: 0.01 mg/L, 0.01℃ 655 655 656 656 * **Maximum operating pressure**: 6 bar 657 657 ... ... @@ -659,7 +659,9 @@ 659 659 660 660 * **Power supply voltage**: 5-24V DC 661 661 662 -* **Working environment**: temperature 0-60°C; humidity <95%RH 664 +* **Working environment:** 665 +** Ambient Temperature: 0–60°C 666 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 663 663 664 664 * **Power consumption**: ≤0.5W 665 665 ... ... @@ -774,7 +774,7 @@ 774 774 == 5.1 Specification == 775 775 776 776 777 -* **Measuring range**: 0.11000.0NTU 781 +* **Measuring range**: 0.1~~1000.0NTU 778 778 779 779 * **Accuracy**: ±5% 780 780 ... ... @@ -782,11 +782,13 @@ 782 782 783 783 * **Stability**: ≤3mV/24 hours 784 784 785 -* **Output signal**: A: 420 mA (current loop)B:RS485 (standard Modbus-RTU protocol, device default address: 01)789 +* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 786 786 787 -* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 791 +* **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 788 788 789 -* **Working environment**: temperature 060°C; humidity ≤ 95%RH 793 +* **Working environment:** 794 +** Ambient Temperature: 0–60°C 795 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 790 790 791 791 * **Power consumption**: ≤ 0.5W 792 792 ... ... @@ -875,3 +875,9 @@ 875 875 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 876 876 877 877 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 884 + 885 + 886 += 6. Water Quality Sensor Datasheet = 887 + 888 + 889 +* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
- image-20241129142314-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.2 MB - Content