Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -100,6 +100,7 @@ 100 100 101 101 * The equipment should be calibrated before each use. It is recommended to calibrate it every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). 102 102 103 + 103 103 == 1.7 RS485 Commands == 104 104 105 105 ... ... @@ -125,6 +125,7 @@ 125 125 |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 126 126 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 127 127 129 + 128 128 === 1.7.2 Change address === 129 129 130 130 ... ... @@ -162,6 +162,7 @@ 162 162 0X8F 163 163 ))) 164 164 167 + 165 165 === 1.7.4 Query data === 166 166 167 167 ... ... @@ -248,6 +248,7 @@ 248 248 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 high 249 249 |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50 250 250 254 + 251 251 = 2. DR-PH01 Water PH Sensor = 252 252 253 253 == 2.1 Specification == ... ... @@ -277,6 +277,7 @@ 277 277 278 278 * **Max Pressure**: 0.6MPa 279 279 284 + 280 280 == 2.2 Wiring == 281 281 282 282 ... ... @@ -338,6 +338,7 @@ 338 338 339 339 * The equipment should be calibrated before each use. For long-term use, it is recommended to calibrate once every 3 months. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). After aging, the electrodes should be replaced in time. 340 340 346 + 341 341 == 2.6 RS485 Commands == 342 342 343 343 ... ... @@ -482,6 +482,7 @@ 482 482 483 483 * **Max Pressure**: 0.6MPa 484 484 491 + 485 485 == 3.2 Wiring == 486 486 487 487 ... ... @@ -552,6 +552,7 @@ 552 552 |=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Original address|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 64.75px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 high 553 553 |(% style="width:99px" %)0XFE |(% style="width:112px" %)0X03|(% style="width:135px" %)0X00|(% style="width:126px" %)0X50|(% style="width:85px" %)0X00|(% style="width:1px" %)0X00|(% style="width:1px" %)0X51|(% style="width:1px" %)0XD4 554 554 562 + 555 555 **response:** 556 556 557 557 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) ... ... @@ -558,6 +558,7 @@ 558 558 |=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 559 559 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 560 560 569 + 561 561 === 3.6.2 Change address === 562 562 563 563 ... ... @@ -595,6 +595,7 @@ 595 595 0X96 596 596 ))) 597 597 607 + 598 598 === 3.6.4 Query data === 599 599 600 600 ... ... @@ -672,10 +672,13 @@ 672 672 == 4.3 Impedance requirements for current signals == 673 673 674 674 675 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:40 0px" %)676 -|(% style="width:1 32px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**677 -|(% style="width:13 2px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**685 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 686 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 687 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 678 678 689 +[[image:image-20240718195414-8.png||height="100" width="575"]] 690 + 691 + 679 679 == 4.4 Mechinical Drawing == 680 680 681 681 ... ... @@ -689,6 +689,7 @@ 689 689 690 690 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 691 691 705 + 692 692 == 4.6 RS485 Commands == 693 693 694 694 ... ... @@ -732,6 +732,7 @@ 732 732 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 733 733 |(% style="width:99px" %)0X01|(% style="width:72px" %)0X10|(% style="width:64px" %)0X00|(% style="width:68px" %)0X0A|(% style="width:70px" %)0X00|(% style="width:72px" %)0X02|(% style="width:56px" %)0X61|(% style="width:56px" %)0XCA 734 734 749 + 735 735 === 4.6.3 Query data === 736 736 737 737 ... ... @@ -799,10 +799,11 @@ 799 799 == 5.3 Impedance requirements for current signals == 800 800 801 801 802 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:40 0px" %)803 -|(% style="width:1 32px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**804 -|(% style="width:13 2px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**817 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 818 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 819 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 805 805 821 + 806 806 == 5.4 Mechinical Drawing == 807 807 808 808