Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,8 +19,8 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 2~~ 2,000 μS/cm Resolution: 1 μS/cm23 -** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm22 +** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 26 ... ... @@ -557,7 +557,6 @@ 557 557 |=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 558 558 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 559 559 560 - 561 561 === 3.6.2 Change address === 562 562 563 563 ... ... @@ -642,7 +642,6 @@ 642 642 0XC3 643 643 ))) 644 644 645 - 646 646 = 4. DR-DO1 Dissolved Oxygen Sensor = 647 647 648 648 == 4.1 Specification == ... ... @@ -664,7 +664,6 @@ 664 664 665 665 * **Power consumption**: ≤0.5W 666 666 667 - 668 668 == 4.2 wiring == 669 669 670 670 ... ... @@ -678,7 +678,6 @@ 678 678 |(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 679 679 |(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 680 680 681 - 682 682 == 4.4 Mechinical Drawing == 683 683 684 684 ... ... @@ -692,7 +692,6 @@ 692 692 693 693 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 694 694 695 - 696 696 == 4.6 RS485 Commands == 697 697 698 698 ... ... @@ -778,7 +778,7 @@ 778 778 == 5.1 Specification == 779 779 780 780 781 -* **Measuring range**: 0.11000.0NTU 776 +* **Measuring range**: 0.1~~1000.0NTU 782 782 783 783 * **Accuracy**: ±5% 784 784 ... ... @@ -794,7 +794,6 @@ 794 794 795 795 * **Power consumption**: ≤ 0.5W 796 796 797 - 798 798 == 5.2 wiring == 799 799 800 800 ... ... @@ -808,7 +808,6 @@ 808 808 |(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 809 809 |(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 810 810 811 - 812 812 == 5.4 Mechinical Drawing == 813 813 814 814 ... ... @@ -822,7 +822,6 @@ 822 822 823 823 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 824 824 825 - 826 826 == 5.6 RS485 Commands == 827 827 828 828 ... ... @@ -882,3 +882,11 @@ 882 882 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 883 883 884 884 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 877 + 878 + 879 += 6. Water Quality Sensor Datasheet = 880 + 881 + 882 +* **[[WQS-xS_Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]** 883 + 884 +