... ... @@ -32,6 +32,7 @@
32 32  
33 33  * **Max Pressure**: 0.6MPa
34 34  
35 +
35 35  == 1.2 Application for Different Range ==
36 36  
37 37  
... ... @@ -99,6 +99,7 @@
99 99  
100 100  * The equipment should be calibrated before each use. It is recommended to calibrate it every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.).
101 101  
103 +
102 102  == 1.7 RS485 Commands ==
103 103  
104 104  
... ... @@ -124,6 +124,7 @@
124 124  |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high
125 125  |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0
126 126  
129 +
127 127  === 1.7.2 Change address ===
128 128  
129 129  
... ... @@ -161,6 +161,7 @@
161 161  0X8F
162 162  )))
163 163  
167 +
164 164  === 1.7.4 Query data ===
165 165  
166 166  
... ... @@ -247,6 +247,7 @@
247 247  |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 high
248 248  |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50
249 249  
254 +
250 250  = 2. DR-PH01 Water PH Sensor =
251 251  
252 252  == 2.1 Specification ==
... ... @@ -276,6 +276,7 @@
276 276  
277 277  * **Max Pressure**: 0.6MPa
278 278  
284 +
279 279  == 2.2 Wiring ==
280 280  
281 281  
... ... @@ -337,6 +337,7 @@
337 337  
338 338  * The equipment should be calibrated before each use. For long-term use, it is recommended to calibrate once every 3 months. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). After aging, the electrodes should be replaced in time.
339 339  
346 +
340 340  == 2.6 RS485 Commands ==
341 341  
342 342  
... ... @@ -481,6 +481,7 @@
481 481  
482 482  * **Max Pressure**: 0.6MPa
483 483  
491 +
484 484  == 3.2 Wiring ==
485 485  
486 486  
... ... @@ -551,6 +551,7 @@
551 551  |=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Original address|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 64.75px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 high
552 552  |(% style="width:99px" %)0XFE |(% style="width:112px" %)0X03|(% style="width:135px" %)0X00|(% style="width:126px" %)0X50|(% style="width:85px" %)0X00|(% style="width:1px" %)0X00|(% style="width:1px" %)0X51|(% style="width:1px" %)0XD4
553 553  
562 +
554 554  **response:**
555 555  
556 556  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %)
... ... @@ -595,6 +595,7 @@
595 595  0X96
596 596  )))
597 597  
607 +
598 598  === 3.6.4 Query data ===
599 599  
600 600  
... ... @@ -642,7 +642,6 @@
642 642  0XC3
643 643  )))
644 644  
645 -
646 646  = 4. DR-DO1 Dissolved Oxygen Sensor =
647 647  
648 648  == 4.1 Specification ==
... ... @@ -664,7 +664,6 @@
664 664  
665 665  * **Power consumption**: ≤0.5W
666 666  
667 -
668 668  == 4.2 wiring ==
669 669  
670 670  
... ... @@ -674,11 +674,13 @@
674 674  == 4.3 Impedance requirements for current signals ==
675 675  
676 676  
677 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %)
678 -|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
679 -|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
685 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %)
686 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V**
687 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω**
680 680  
689 +[[image:image-20240718195414-8.png||height="100" width="575"]]
681 681  
691 +
682 682  == 4.4 Mechinical Drawing ==
683 683  
684 684  
... ... @@ -736,6 +736,7 @@
736 736  |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high
737 737  |(% style="width:99px" %)0X01|(% style="width:72px" %)0X10|(% style="width:64px" %)0X00|(% style="width:68px" %)0X0A|(% style="width:70px" %)0X00|(% style="width:72px" %)0X02|(% style="width:56px" %)0X61|(% style="width:56px" %)0XCA
738 738  
749 +
739 739  === 4.6.3 Query data ===
740 740  
741 741  
... ... @@ -803,9 +803,9 @@
803 803  == 5.3 Impedance requirements for current signals ==
804 804  
805 805  
806 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %)
807 -|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
808 -|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
817 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %)
818 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V**
819 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω**
809 809  
810 810  
811 811  == 5.4 Mechinical Drawing ==
... ... @@ -821,7 +821,6 @@
821 821  
822 822  * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently.
823 823  
824 -
825 825  == 5.6 RS485 Commands ==
826 826  
827 827  