Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,8 +19,8 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 2~~ 2,000 μS/cm Resolution: 1 μS/cm23 -** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm22 +** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 26 ... ... @@ -675,7 +675,6 @@ 675 675 |(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 676 676 |(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 677 677 678 - 679 679 == 4.4 Mechinical Drawing == 680 680 681 681 ... ... @@ -774,7 +774,7 @@ 774 774 == 5.1 Specification == 775 775 776 776 777 -* **Measuring range**: 0.11000.0NTU 776 +* **Measuring range**: 0.1~~1000.0NTU 778 778 779 779 * **Accuracy**: ±5% 780 780 ... ... @@ -799,9 +799,9 @@ 799 799 == 5.3 Impedance requirements for current signals == 800 800 801 801 802 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:4 20px" %)803 -| =(% style="width:40px" %)Supply Voltage|=(% style="width:0px;" %)9V|=(% style="width:0px;" %)**12V**|=(% style="width:0px;" %)**20V**|=(% style="width:0px;" %)**24V**804 -|(% style="width:13 7px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω**801 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %) 802 +|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 803 +|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 805 805 806 806 == 5.4 Mechinical Drawing == 807 807 ... ... @@ -875,3 +875,11 @@ 875 875 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 876 876 877 877 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 877 + 878 + 879 += 6. Water Quality Sensor Datasheet = 880 + 881 + 882 +* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]** 883 + 884 +