From version < 46.2 >
edited by Xiaoling
on 2024/08/07 09:07
To version < 50.1 >
edited by Xiaoling
on 2024/10/24 17:50
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,8 +19,8 @@
19 19  * **EC Range & Resolution:**
20 20  ** **ECK0.01** : 0.02 ~~ 20 μS/cm
21 21  ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm
22 -** **ECK1.0** : 2 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 -** **ECK10.0** : 20 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
22 +** **ECK1.0** : 0 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 +** **ECK10.0** : 10 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
24 24  
25 25  * **EC Accuracy**: ±1% FS
26 26  
... ... @@ -675,7 +675,6 @@
675 675  |(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
676 676  |(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
677 677  
678 -
679 679  == 4.4 Mechinical Drawing ==
680 680  
681 681  
... ... @@ -774,7 +774,7 @@
774 774  == 5.1 Specification ==
775 775  
776 776  
777 -* **Measuring range**: 0.11000.0NTU
776 +* **Measuring range**: 0.1~~1000.0NTU
778 778  
779 779  * **Accuracy**: ±5%
780 780  
... ... @@ -799,9 +799,9 @@
799 799  == 5.3 Impedance requirements for current signals ==
800 800  
801 801  
802 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %)
803 -|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V**
804 -|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω**
801 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %)
802 +|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
803 +|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
805 805  
806 806  == 5.4 Mechinical Drawing ==
807 807  
... ... @@ -875,3 +875,11 @@
875 875  For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C
876 876  
877 877  02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU
877 +
878 +
879 += 6.  Water Quality Sensor Datasheet =
880 +
881 +
882 +* **[[WQS-xS_Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
883 +
884 +
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0