Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
<
edited by Karry Zhuang
on 2025/02/18 15:43
on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.karry - Content
-
... ... @@ -19,15 +19,14 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 2~~ 2,000 μS/cm Resolution: 1 μS/cm23 -** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm22 +** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 - 27 -* **Temperature Measure Range**: -20 ~~ 60 °C 28 - 29 29 * **Temperature Accuracy: **±0.5 °C 30 - 27 +* **Working environment:** 28 +** Ambient Temperature: 0–60°C 29 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 31 * **IP Rated**: IP68 32 32 33 33 * **Max Pressure**: 0.6MPa ... ... @@ -41,7 +41,7 @@ 41 41 == 1.3 Wiring == 42 42 43 43 44 -[[image:image-2024 0720172533-1.png||height="347" width="569"]]43 +[[image:image-20241129142314-1.png||height="352" width="1108"]] 45 45 46 46 47 47 == 1.4 Mechinical Drawing == ... ... @@ -268,7 +268,9 @@ 268 268 269 269 * **Temperature measurement error**: ±0.5°C 270 270 271 -* **Temperature Measure Range**: -20 ~~ 60 °C 270 +* **Working environment:** 271 +** Ambient Temperature: 0–60°C 272 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 272 272 273 273 * **Temperature Accuracy: **±0.5 °C 274 274 ... ... @@ -475,7 +475,9 @@ 475 475 476 476 * **Stability**: ≤2mv/24 hours 477 477 478 -* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 479 +* **Working environment:** 480 +** Ambient Temperature: 0–60°C 481 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 479 479 480 480 * **IP Rated**: IP68 481 481 ... ... @@ -646,11 +646,11 @@ 646 646 == 4.1 Specification == 647 647 648 648 649 -* **Measuring range**: 0-20mg/L, 0 -50°C652 +* **Measuring range**: 0-20mg/L, 0–50℃ 650 650 651 -* **Accuracy**: 3%, ±0.5 °C654 +* **Accuracy**: 3%, ±0.5℃ 652 652 653 -* **Resolution**: 0.01 mg/L, 0.01 °C656 +* **Resolution**: 0.01 mg/L, 0.01℃ 654 654 655 655 * **Maximum operating pressure**: 6 bar 656 656 ... ... @@ -658,7 +658,9 @@ 658 658 659 659 * **Power supply voltage**: 5-24V DC 660 660 661 -* **Working environment**: temperature 0-60°C; humidity <95%RH 664 +* **Working environment:** 665 +** Ambient Temperature: 0–60°C 666 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 662 662 663 663 * **Power consumption**: ≤0.5W 664 664 ... ... @@ -671,13 +671,10 @@ 671 671 == 4.3 Impedance requirements for current signals == 672 672 673 673 674 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:4 20px" %)675 -| =(% style="width:40px" %)Supply Voltage|=(% style="width:0px;" %)9V|=(% style="width:0px;" %)**12V**|=(% style="width:0px;" %)**20V**|=(% style="width:0px;" %)**24V**676 -|(% style="width:13 7px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω**679 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %) 680 +|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 681 +|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 677 677 678 -[[image:image-20240718195414-8.png||height="100" width="575"]] 679 - 680 - 681 681 == 4.4 Mechinical Drawing == 682 682 683 683 ... ... @@ -691,7 +691,6 @@ 691 691 692 692 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 693 693 694 - 695 695 == 4.6 RS485 Commands == 696 696 697 697 ... ... @@ -735,7 +735,6 @@ 735 735 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 736 736 |(% style="width:99px" %)0X01|(% style="width:72px" %)0X10|(% style="width:64px" %)0X00|(% style="width:68px" %)0X0A|(% style="width:70px" %)0X00|(% style="width:72px" %)0X02|(% style="width:56px" %)0X61|(% style="width:56px" %)0XCA 737 737 738 - 739 739 === 4.6.3 Query data === 740 740 741 741 ... ... @@ -778,7 +778,7 @@ 778 778 == 5.1 Specification == 779 779 780 780 781 -* **Measuring range**: 0.11000.0NTU 781 +* **Measuring range**: 0.1~~1000.0NTU 782 782 783 783 * **Accuracy**: ±5% 784 784 ... ... @@ -786,11 +786,13 @@ 786 786 787 787 * **Stability**: ≤3mV/24 hours 788 788 789 -* **Output signal**: A: 420 mA (current loop)B:RS485 (standard Modbus-RTU protocol, device default address: 01)789 +* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 790 790 791 -* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 791 +* **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 792 792 793 -* **Working environment**: temperature 060°C; humidity ≤ 95%RH 793 +* **Working environment:** 794 +** Ambient Temperature: 0–60°C 795 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 794 794 795 795 * **Power consumption**: ≤ 0.5W 796 796 ... ... @@ -803,11 +803,10 @@ 803 803 == 5.3 Impedance requirements for current signals == 804 804 805 805 806 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:4 20px" %)807 -| =(% style="width:40px" %)Supply Voltage|=(% style="width:0px;" %)9V|=(% style="width:0px;" %)**12V**|=(% style="width:0px;" %)**20V**|=(% style="width:0px;" %)**24V**808 -|(% style="width:13 7px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω**808 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %) 809 +|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 810 +|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 809 809 810 - 811 811 == 5.4 Mechinical Drawing == 812 812 813 813 ... ... @@ -880,3 +880,9 @@ 880 880 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 881 881 882 882 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 884 + 885 + 886 += 6. Water Quality Sensor Datasheet = 887 + 888 + 889 +* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
- image-20241129142314-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.2 MB - Content